Blower Motor Installation - Thermador VCIN60RP Instrucciones De Instalación

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

c) Install strain relief (not included) into one of the
circular knockouts.
6. Install the unit.
a) Install the custom insert inside the custom housing.
b) Secure to the rear of the housing framework using
six (6) x 1'' (25.4 mm) mounting screws, as
indicated in Figure 10.
c) Secure to the sides of the housing framework using
eight (8) x 1'' (25.4 mm) mounting screws, 4 per
side as indicated in Figure 11.
7. Connect to the ductwork.
Installation Instructions
Figure 9: Strain Relief
Figure 10: Rear Screws
Figure 11: Side Screws
8. Install the blower motor.
a) Refer to "Choosing the Correct Blower" on
page 11.
b) Refer to "Blower Motor Installation" beginning on
page 13.
9. Connect the electrical wiring.
a) Connect wiring for applicable blower motor (see
blower instructions beginning on page 13).
10. Install hood filters and grease trays.
a) Refer to "Installing Grease Trays and Filters" on
page 19.
11. Test the installation.
a) Test the operation of the blower and the lights.
b) Be sure to check for backdraft. With the blower on
high, close the windows and doors to the area to
ensure that fan does not cause back drafting in any
outlet vent for another appliance.

Blower Motor Installation

Blower
SKU
Integral
VTN1090*
120
Remote
VTR1030*
120
Remote
VTR1330*
120
Inline
VTI1010*
120
* Indicates a letter designating the release year.
** With blower installed.
Integral blower installation only
1. The blower is attached to the hood using weld studs on
the mounting plate. Figure 12 exhibits the weld stud
locations.
2. Guide the motor mounting plate over the studs.
Voltage
Current
Amps**
5.7
15
5.7
15
8.5
15
5.7
15
Figure 12: Weld Stud Location
English | 13 |