Rule iD20 Manual Del Usuario página 2

Bomba de inflado / desinflado de alta velocidad
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

High Speed Inflator/Deflator
Features
Rapid inflation and deflation of all inflatables.
Inflates a four man dinghy in 1 to 2 minutes.
Deflates, removing every last ounce of air for easy storage.
Adjustable nozzles for all inflatables and valve types.
Light weight and easy to use.
Easier and faster than manual pumps.
Temperature sensitive air release valve protects from overheating and
over inflating.
Robust long life construction.
Operating Instructions
If these simple instructions are followed then your High Speed Inflator / Deflator will take the
hassle out of inflating and deflating your dinghy for many years to come.
1. Make sure the correct adaptor is selected to suit your valve (see diagrams showing typical
valve assemblies). Failure to use the correct adaptor will reduce performance and create
back pressure which causes unwanted heat.
2. Insert adaptor into inflate / deflate port of the High Speed Inflator.
3. Ensure your battery is in good condition and has a sufficient capacity of 45 AH minimum.
4. Uncoil cable, connect the red (+) battery clip to the positive terminal and the black
(-) battery clip to the negative terminal.
5. Fully engage the adaptor into the dinghy valve and completely depress the switch.
Safety
If the Inflator is connected to a circuit using connections other than the battery clips
supplied the connecting fuses should be rated at 25 amps at 12 volts DC. Cigar lighter
sockets are NOT suitable.
Do not try to over-inflate the dinghy. The High Speed Inflator will give between 0.18 and
0.21 bar (2.6 and 3.0 p.s.i.), which is suitable in most instances. If extra pressure is required,
top up with a manual pump.
When maximum inflation / deflation is reached you will note a change of tone. If the unit is
left running after the tone change no more pressure will be achieved and the air retained in
the pump chamber will heat rapidly. The temperature sensitive air release valve will open,
releasing the hot air and protecting the unit from over heating. However, it will not protect
the unit indefinitely and the unit should be switched off immediately the change of tone is
heard and the release valve starts to vent air. On cooling the air release valve will reset.
The inflator should not be placed bottom down on a surface when operating as the air
release valve will not function.
The lead can be extended to 20 ft (6 m) without significantly affecting performance.
The minimal cross sectional area of the extending cable should be 10 AWG copper wire
(2.5mm
2
). For longer extensions the cable should be 8 AWG copper wire (4.0mm
minimum.
Store away from excessive heat and direct sunlight to avoid external damage.
pump fails to perform, check for blockages, air leaks and correct electrical and adaptor
connections.
Unwrap cables fully before use.
operation only.
Do NOT immerse in water.
Do NOT secure in 'ON' position - hand
2
)
If the

Publicidad

Tabla de contenido
loading

Tabla de contenido