4
Technical data
4.1
Water management system
For rated voltage, rated current, frequency and/or input power, refer to the country-specific type
identification plate.
If the tool is powered by a generator or transformer, the generator or transformer's power output must be
at least twice the rated input power shown on the rating plate of the tool. The operating voltage of the
transformer or generator must always be within +5 % and -15 % of the rated voltage of the tool.
Protection class
Protection class
Weight in accordance with EPTA procedure 01/2003
Weight of the hose set
Operating temperature
Recommended temperature range for transport and storage
(without water in the container)
Suction hose length
Pressure hose length
Supply cord length
Container capacity
Water capacity
Volumetric flow rate (air)
Water flow rate
Water pressure
4.2
Bluetooth
Frequency band
Maximum emitted transmission power
4.3
Noise and vibration information (measured in accordance with EN 60335-2-69):
Typical A-weighted emission sound pressure level
Uncertainty for the given sound levels
Triaxial vibration value (vibration vector sum)
Uncertainty for the given vibration value
5
Before use
5.1
Filling the water and waste material container
1. Open the two catches.
2. Remove the filter bag. → page 22
3. Fill the water container with water up to the MAX mark.
When the "Water level too high" warning lamp lights, the appliance cannot be operated.
The water and waste material container must be filled for the "Water supply" and "Recycling"
modes.
4. Insert the filter bag. → page 21
5. Fit the top section of the appliance onto the water and waste material container.
6. Close the two catches.
20
English
I
IPX4
19.7 kg
1.8 kg
3 ℃ ... 40 ℃
−25 ℃ ... 70 ℃
5 m
5.1 m
4.8 m
32 ℓ
14 ℓ
74 ℓ/s
3 ℓ/min
7 bar
2,400 MHz ... 2,483 MHz
10 dBm
≤ 76 dB
2 dB
2.5 m/s²
≤ 0.2 m/s²
2
2154323
*2154323*