Preparations; Removing The Packaging - THERMOBILE IMAC 4000 Manual Del Usario

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 42
English
S
Hot-air outlet
T
Armature nut
2.4
Main components of the burner (Fig.
6)
A
Burner automat
B
Burner head with fan, nozzle, electrodes and
forcer plate
C
Photocell
D
Burner motor
E
Magnet valves
F
Fuel pump
G
Ignition transformer
2.5
Control panel (Fig. 7)
A
Indicator light, blue: Fan high speed
B
Indicator light, blue: Fan low speed
C
Indicator light, white: Panel is live
D
Indicator light, orange: Burner low
E
Indicator light, orange: Burner high
F
Hour counter
G
Pushbutton with indicator light, red: Fault
frequency controller and reset
H
Indicator light, red: Maximum temperature
I
Pushbutton with indicator light, red: Fault
burner and reset
J
Switch for fan and burner settings:
-
0: The convector heater is switched off
-
1: Fan low speed
-
2: Fan high speed
-
3: Fan low speed; burner low
-
4: Fan high speed; burner low
-
5: Fan high speed; burner high
K
Digital thermostat
2.6
Digital thermostat
The digital thermostat (K) has three functions:
Fan thermostat:
After switching off the convector heater, the
ventilator will continue to run. The ventilator
will cool down the convector heater to
prevent damage by overheating. As soon as
the temperature has dropped sufficiently, the
thermostat will turn off the fan.
Burner thermostat:
The thermostat will stop the burner as soon
as the temperature of the hot air has risen too
much.
When the air temperature has dropped
sufficiently, the thermostat will turn on the
burner again.
Maximum thermostat:
The maximum thermostat will switch off the
convector heater completely if an
overheating problem has occurred in the
convector heater. The burner cannot be
16
switched on again until the thermostat has
been reset by pressing the U key for two
seconds.
2.7
Fuel tank
Thermostat for room temperature
Air-supply hose (diameter 500 or 600 mm)
Air-inlet panels (diameter 500 or 600 mm)
Hot air outlets (diameter 2 x 600 mm or 3 x
500 mm)
Fresh-air connection for the burner.
3
3.1
1.
Remove packaging from the convector
heater
2.
Lift the convector heater to transport it to its
location of use.
3.2
1.
Make sure the convector heater is level.
2.
Connect the fuel supply to the quick coupling
(A) of the convector heater, see fig. 8.
3.
Fill the tank with fuel.
4.
Make sure there is sufficient distance
between the wall and the air inlet. Minimum
distance is 1 m.
5.
Ensure that the heated air is allowed to flow
freely. The minimum distance between the
outlet and any obstacle is 5 m.
6.
Check the ventilation surface: per kW, a
surface area of 25 cm
7.
Check the connection of the room
thermostat.
Do not remove the cap if you do not use a
room thermostat.
40.020.949 - rev. 05 - 2011
Accessories

PREPARATIONS

Removing the packaging

Caution
Lift the convector heater according to
the instructions on the labels.
Installation
Caution
Use diesel oil only.
Caution
Dieseloil tends to thicken at low
temperatures. This may clog the
filters. Add max. 15% paraffin oil to
the fuel if the temperature has
dropped below -5°C, or make sure
the fuel is frost-free, or use the
(optional) tank-heating device.
Do not place the tank in the hot-air
flow.
2
is required.