6. Description and function

6.1 Product description

FIG. 1
A - X-Care
B - Pressure sensor
C - Speed sensor
D - Cartridge seal
E - Cartridge seal connector
6.2 Design of product
• X-Care device is available on all Nexis pumps.
• It detects abnormal operations like dry running or
remaining air at the top of the pump that could
lead to mechanical seal failure.
• One dry contact relay allows defect monitoring if
selected. When it is wired to a supply contactor
that could protect pump in an effective way.
• Communication features allow status and data
exchange to supervisory control system.

6.3 Description of display

Display overview
1
2
3
4
5
6
Pos.
Description
1
Power supply indicator
2
Direction of rotation indicator
3
Other defects indicator
4
Dry-running detection indicator
5
Infrared window
6
Infrared data transfer led
SALMSON 12/2013
Display description
Symbol
Colour
OFF
White
OFF
Green
Red
OFF
Red
OFF
Red
OFF
Green
Blinking
Green (2Hz)
6.2 Relay operations
• X-Care is equipped with one dry contact relay in
order to prevent any defect occurrence. To pro-
tect pump efficiently, it must be wired to pump
power supply.
• Relay could be set as 'normally opened mode or
'normally closed' mode depending on the
cabling.
• Every defect has got a maximum number of
occurrences per day, starting from X-Care power
on (see chapter 10 faults, causes and remedies).
Once this maximum number is reached, relay
stays blocked until any involved adjustment to
keep it re-active again (see chapter 10 faults,
causes and remedies).
Yes
Defects
1
2
3
No
Open
Dry
contact
(normally
open wiring)
closed
24H00 sliding
Description
X-Care power OFF
X-Care power ON
Pump is deactivated
Direction of rotation
is correct
Direction of rotation
is not correct
No defect
Occurrence of one defect
(out of dry-running detection)
No defect
Dry-running detection
Infrared communication is
inactive
Infrared communication is
enabled
Infrared communication is in
progress
4
5
6
7
8