8-Clean the enclosure with soft dry cloth after disconnecting the power cable.
9-Protect the machine from splash of rain or water to avoid electric shock or fire, and keep it away from
any location with high temperature or humidity.
10-For reason of personal safety, do not dismantle the enclosure for repair or change on your own.
Other considerations:
1-During normal operation of ultrasonic generator, a consistent sound is resulted from the harmonic
oscillation of the tank body impacted by ultrasound wave, and no agitation but ripple is caused on the
surface of cleaning fluid by explosion of cavity. In case of discontinuous oscillation, increase or reduce
the cleaning fluid by a small quantity to eliminate such oscillation to facilitate cleaning ofwork piece.
2-While ensuring adequate cleaning of work piece, keep the generator operating intermittently, as long-
term consecutive operation may result in high temperature insides and accelerate aging of
electroniccomponents in it.
3-Absolutely do not use any inflammable detergent.
4-Start heating or ultrasonic wave generator only when the cleaning tank contains fluid, or otherwise the
machine may be burnt out or even result in fire.
5-Prevent splash of cleaning fluid or water into the machine or energy converter, which may cause electric
leakage or short circuiting, and thereby damage to the converter.
6-Any foreign matter falling into the tank shall be taken out immediately.
7-Before changing or discharging the cleaning fluid, make sure the fluid is at normal temperature and the
ultrasonic wave generator is shut down and the power supply is disconnected.
8-Remove any dirt in the tank after operation.
9-Keep the external surface of the machine clean.