Troubleshooting
Power LED off.
DC power fault - check connection to power supply.
Ensure PS50 power supply is connected to an AC
power source.
Charge status LED does
Battery is not fully inserted.
not illuminate.
Battery does not charge
Battery discharged below 3.0 volts. Try another
battery.
Specifications- AXT903/904 Portable Battery Chargers
Battery Type
Up to 2 rechargeable Li-Ion batteries (AXT910/AXT920/920SL)
Charge Time
50%=1 hour; 100%=3 hours
Operating Temperature
-18°C (0°F) to +40°C (104°F)
Range
Battery Charging
0°C (32°F) to 60°C (140°F)
Temperature Range
Storage Temperature
-29°C (-20°F) to 74°C (165°F), without batteries
Range
Dimensions
45 mm x 86 mm x 114 mm (1.8 in. x 3.4 in. x 4.5 in.), H x W x D
Weight
350 g (12.3 oz.), without batteries or PS50 External Power Supply
Housing
Cast and extruded aluminum
Power Requirements
5.5 V DC, 2.72 A