MANUAL DE FUNCIONAMIENTO Y MONTAJE DE LA UNIDAD COMBI DE BOMBA DE CALOR PKOM
18.7 CERTIFICADO PASSIVHAUS EXPEDI-
DO POR EL PHI
Certificate
Passive House Suitable Component
For cool temperate climates
Category:
Manufacturer:
Product name:
This certificate was awarded based on the following
criteria (limit values*):
Thermal Comfort:
Heat Recovery of ventilation system:
Electric efficiency ventilation system:
Air tightness (internal/external):
Total Primary Energy Demand (**):
Control and calibration (*)
Air pollution filters (*)
Anti freezing strategy (*)
Noise emission and reduction (*)
Measured values to be used in PHPP
useful air flow rates 121 to 192 m³/h
Heating
Outside Air
Temperature
Thermal Output
Heating Heat Pump
COP number Heating
Heat Pump
Maximum available supply air
temperature with Heat Pump only(*)
Hot water
Outside Air
Temperature
Thermal Output Heat
Pump for heating up
storage tank.
Thermal Output Heat
Pump for reheating
storage tank
COP Heat Pump for
heating up storage tank
COP Heat Pump for
reheating storage tank
Average storage tank temperature
Specific storage heat losses
Exhaust air addition (if applicable)
(*) detailed description of criteria and key values see attachment.
(**) for heating, domestic hot water (DHW), ventilation, auxiliary electricity in the reference
building, explanation see attachment.
(***) All key values of heat pump were measured with enthalpy (humid) heat exchanger.
The dry heat recovery was measured, too and is shown here alternatively.
All other key values are valid respectively for dry heat recovery, too.
www.passivehouse.com
Puede descargar el certificado actual en: www.pichlerluft.at/waermepumpenkombigeraete.html
Compact Heat Pump System
Pichler G.m.b.H.
9021 Klagenfurt, AUSTRIA
PKOM 4
θ
supply air
η
WRG,eff
P
el
V
Leakage
PE
total
Test point 1
Test point 3
Test point 3
-15
-7
T
amb
0.612
0.933
P
WP,Heiz
1.53
2.61
COP
Heiz
33
Test point 1
Test point 3
Test point 3
-7
2
T
amb
P
0.84
1.15
DHW
heating up
P
0.80
1.19
DHW
reheating
COP
2.28
2.97
DHW,
heating up
COP
2.02
2.88
DHW
reheating
45
1.51
200
4
Passivhaus Institut
Dr. Wolfgang Feist
64283 Darmstadt
GERMANY
Heat Recovery by
≥ 16.5°C
≥ 75%
≤ 0.45 Wh/m³
Dry Heat Recovery by
≤ 3%
heat exchanger(***)
≤ 55 kWh/(m²a)
Electric efficiency
Test point 4
2
7
°C
V
0.771
0.776
kW
3.15
3.86
-
°C
Test point 4
7
20
°C
Total Primary Energy
1.38
1.67
kW
1.35
1.66
kW
3.34
3.94
-
3.10
3.76
-
°C
W/K
m³/h
0875ch03
enthalpy heat
exchanger(***)
η
= 85%
WRG,eff
alternative:
η
= 88%
WRG,eff
0.33 Wh/m³
Air tightness
V
= 0.8%
leak, internal
= 1.4%
leak, external
Frost protection
down to -15 °C
Demand (**)
45 kWh/(m²a)
PÁGINA 59