thoroughly decarbonized and the crankcase must be flushed
before conversion.
OPERATION
PRIOR TO OPERATION _____________________________
1. Ensure that the power source to be utilized conforms to the
power source requirements specified on the product nameplate.
See ELECTRICAL WIRING & GROUNDING for more
information.
2. Ensure that the lever of the pressure switch is in the "OFF"
position. If the plug is connected to a outlet while the knob is in
the "ON/AUTO" position, the compressor will start operating
immediately and can cause serious injury.
A = "ON/AUTO"
B = "OFF"
3. Use a screwdriver or similar tool to remove the plastic shipping
cap from the oil fill hole.
4. Pour "All-Season Select" or other approved oil into the oil fill hole
to the level indicated on the dipstick provided. See
COMPRESSOR LUBRICATION for more information.
A = Maximum Oil Level
B = Minimum Oil Level
5. Install the dipstick in the oil fill hole.
6. Insert the plug into the outlet. If the power outlet only loosely
accepts the plug, the outlet must be repaired. Contact a qualified
electrician for repair service. The use of a faulty outlet may
cause overheating, resulting in a serious hazard.
Drain the tank to release air pressure before
WARNING
removing the dipstick.
Make sure the air vent in the dipstick is free
WARNING
from debris. If the air vent is blocked, pressure
can build in the crankcase and cause damage
to the compressor and possible personal
injury.
7. Position the compressor on a firm, level surface in a well
ventilated area away from potentially explosive vapors, gases or
other agents. See SELECTING A LOCATION for more
information.
To avoid damaging the compressor, do not
CAUTION
allow the unit to be tilted more than 10° when
operating.
http://air.ingersollrand.com
4
Never operate in temperatures below 32°F
CAUTION
(0°C) or above 104°F (40°C).
STARTING ________________________________________
Wear appropriate personal eye and ear
WARNING
protection during use.
1. Insert the plug into the outlet and start the compressor by turning
the pressure switch lever to "ON/AUTO".
CAUTION
Do not stop or start the compressor by use of
the plug. Always use the lever located on the
pressure switch.
The operation of the compressor is automatic and is controlled
by the pressure switch. The pressure switch stops the
compressor when the pressure in the air tank reaches the
maximum level and restarts the compressor when the air
pressure drops to the restart level.
The motor includes a thermal protection switch which stops the
compressor if the temperature becomes too high. If the switch is
tripped, the compressor will restart only after the reset button is
pushed. See THERMAL OVERLOAD PROTECTION for more
information.
2. Adjust the pressure to the required level by turning the pressure
regulator knob clockwise to increase the pressure and
counterclockwise to decrease the pressure.
A pressure gauge is provided to indicate when the required
pressure is reached.
Prior to using air tools or attachments, check
WARNING
the manufacturer's maximum pressure rating
for that equipment. The compressor outlet
pressure must be regulated to never exceed
the maximum pressure rating of the tools or
attachments.
STOPPING & STORAGE ____________________________
1. Turn the pressure switch lever to "OFF".
2. Unplug the cord from the power source and secure the cord
tightly around the handle.
3. Slowly open the tank drain valve to depressurize the tank and to
empty all accumulated water. Keep your face and eyes away
from the drain valve.
If the tank becomes corroded, there is a risk of
WARNING
breakdown. If the tank is not drained, water will
corrode and weaken the air tank causing a risk
of air tank rupture. Drain the tank daily or after
four hours of use.
4. Store the compressor in a clean, dry location.
P1IU-A9