4.3.7 Reset button
If it is no longer possible to operate the device for any reason (e.g. crash of the running application), the
device can be reset by activating the reset button (keep pressed for at least 4 seconds). The device can be
switched back on as described in chapter 4.1. The reset button is located underneath the cover on the right
side.
4.3.8 Special considerations for external devices at the interfaces
The maximum power consumption of external devices at the COM interface and the 4 USB interfaces must
not exceed 8 Watts.
When connecting external devices to the interfaces, the electrical isolation of the voltage supply ceases to be
effective if the external device has an electrically conductive connection to another electrical supply circuit.
4.4 Battery Operation
The MFT10 is equipped with a rechargeable lithium-ion battery pack. Depending on the power consumption
and temperature the runtime with a fully charged battery is approx. 1.5 hours.