5.0
INSPECTION
5.1
INSPECTION FREQUENCY: The Anchorage System must be inspected prior to use. Inspection frequency, Inspection
fi ndings, date and corrective should be recorded in the "Inspection and Maintenance Log". Inspect all other components of
the Fall Protection System per the frequencies and procedures as defi ned in the respective manufacturer's instructions.
RFID:
Some Anchorage Systems are equipped with an Radio Frequency Identifi cation (RFID) Tag. The RFID Tag can be used in
conjunction with a Handheld Reading Device to simplify inspection and inventory control and provide records for you fall protection
equipment. If you are a fi rst-time user, contact 3M Fall Protection.
Inspect the System for physical damage. Look carefully for any signs of cracks, dents or deformities in the metal.
Make certain components are not deformed in any way and that they move correctly.
Inspect the System for signs of excessive corrosion.
Ensure the condition of the mounting surface will support System loads.
If using a support post, ensure that the base is securely attached to the mounting surface.
Inspect each system component or subsystem (i.e. self retracting lifeline, full body harness, etc.) per associated
manufacturer's instructions.
Record the inspection date and results in the Inspection and Maintenance log.
5.2
DEFECTS: If inspection reveals an unsafe or defective condition, remove the Anchorage System from service
immediately and contact 3M Fall Proection regarding replacement or repair. Do not attempt to repair the
Anchorage System.
5.3
PRODUCT LIFE: The functional life of the Anchorage System is determined by work conditions and maintenance. As long
as the product passes inspection criteria, it may remain in service.
6.0
MAINTENANCE, SERVICING, STORAGE
6.1
CLEANING: Periodically clean the Anchorage System's metal components with a soft brush, warm water, and a mild soap
solution. Ensure parts are thoroughly rinsed with clean water.
6.2
SERVICE: Only 3M Fall Protection or parties authorized in writing by 3M Fall Protection may make repairs to this
equipment. If the Anchorage System has been subject to fall force or inspection reveals an unsafe or defective
conditions, remove the system from service and contact 3M Fall Protection regarding replacement or repair.
6.3
STORAGE AND TRANSPORT: When not in use, or where appropriate, store and transport the Anchorage System and
associated fall protection equipment in a cool, dry, clean environment out of direct sunlight. Avoid areas where chemical
vapors may exist. Thoroughly inspect components after extended storage.