Utility Mode - Bose Panaray System Digital Controller II Guía De Uso

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 32

Utility Mode

Utility Mode
To enter Utility Mode, press and hold the
6
You will have access to the following list of parameters:
Input Sensitivity:
Selects the input sensitivity for both CH1 and CH2 input. There are four selectable parameter
ranges: 0dB, 6dB, 12dB, 18dB.
Output Range:
Selects the output level for both CH1 and CH2 input. Value is universally applied to all four
outputs. There are four selectable parameter ranges: 0dB, 6dB, 12dB, 18dB.
Output Level:
A master output level control is provided to act as a master level control for all four outputs.
The range of the control is 0dB to -60dB, off. These are 1dB increments.
Limiting On/Off:
Activates global protect limiting. Selectable between ON and OFF.
Bass Mono Sum:
This parameter allows the user to SUM all stereo bass to Mono. This would engage the !
following default setting to any Stereo Preset which had the following criteria: Stereo!
Mid/High with Bass.
User Lockout:
In order to prevent customer tampering, a user lockout function is available. This is accessi-
ble via the UTILITY Mode.
When Lockout is engaged, the current state of the controller is fixed.
Note: To disable USER LOCKOUT, the user must simultaneously press and hold the following
buttons for five seconds
ARROW UP
ARROW DOWN
*To EXIT Utility Mode, press the SELECT/LOAD button.
button for 3 seconds.*
SELECT/LOAD

Publicidad

Tabla de contenido
loading

Tabla de contenido