Easy Steps To Operate Your Angelcare; Monitor; Warnings; Instructions - Angelcare AC300 Manual De Uso

Ocultar thumbs Ver también para AC300:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 11

4 EASY STEPS TO OPERATE YOUR ANGELCARE

STEP 1. SENSOR PAD
Position Sensor Pad as illustrated (Figures 1 and 2). The printed side of Sensor Pad MUST face up. DO NOT tuck thick bedding under the edges of the
mattress.
Sensor Pad must rest on a completely flat and rigid surface. If your crib has a flexible or uneven base (metal spring base, etc.), place a piece of
6 mm (1/4") plywood to cover the full size of the crib base.
STEP 2 MONITOR
• Insert 2 AA batteries into Monitor.
• Connect the Sensor Pad cord to the monitor (Figure 3).
• On the side of the Monitor, select 1 of the 2 functions of how you want to monitor your baby:
"Tic" On: To see green movement indicator light flash AND hear a "Tic" sound with every movement baby makes.
"Tic" Off: Same as above BUT without the "Tic" sound.
NOTE: The sensitivity adjustment has been preset. DO NOT ADJUST UNLESS NECESSARY. If poor capture of movement (red flashing
light) or false alarm occurs, consult the Movement Sensitivity Adjustment section.
STEP 3 TO USE MONITOR
Place baby in crib and switch Monitor to the ON position. When removing baby from crib, switch Monitor to the OFF position. If you forget to switch
OFF, a "pre-alarm Tic" will sound after 15 seconds as a reminder.
STEP 4 BATTERY MODE
The Angelcare
®
Movement Monitor is battery operated. Batteries will last approximately 3 to 4 months. When monitor produces a rapid clicking
sound, change batteries promptly.
NOTE:
• Test your Angelcare
®
Monitor BEFORE first-time use and then on a periodic basis.
• When monitor is in use, DO NOT use crib mobile or other crib accessories that produce vibrations. Alarm will not sound as monitor is
still detecting movement.
• The Angelcare
®
Monitor is perfectly safe. The Sensor Pad and the cord are entirely passive. They carry no electrical current and do
not radiate any form of energy.
• Your monitor can be used in any crib or sleeping area (that has NO motion or vibration) designed to safely hold a baby.

Warnings

• This product is NOT a medical device nor a device to prevent cases of
Sudden Infant Death Syndrome (SIDS).
• This product is NOT a substitute for direct supervision of your baby.
Check your baby's activities at regular intervals. Monitoring of
premature babies, or those considered to be at risk, should be carried
out only under the supervision of a doctor or health professional.
• The Sensor Pad may detect movement from many sources from
BOTH inside and outside your baby's room, for example: fans,
washing machines, loud music, etc. Ensure that all vibration
sources are eliminated before using the Angelcare
Avoid contact with crib when monitor is in use. Refer to the
Movement Sensitivity Adjustment and Troubleshooting sections.
• ALWAYS place Monitor on flat surface in an upright position, away
from baby's reach.
• DO NOT touch the end of the adapter cord when plugged into an
electrical outlet.
• This product should be serviced by qualified personnel. There are no
user serviceable parts inside monitor. Refer all service questions to
your distributor (see page 47).

Instructions

RETAIN INSTRUCTIONS: Keep user's manual for future reference.
WATER, MOISTURE AND HEAT DAMAGE: Keep all components away
from water (sink, bath tub, swimming pool) and places that emit heat
(stove, radiator).
VENTILATION: ALWAYS place Monitor on flat surface in an upright
position so that air can flow freely around it.
CORD PROTECTION: Avoid damage to the Sensor Pad cord. The cord is
long enough to route so that it is not likely to be walked on or pinched
by items placed upon or against it.
®

Monitor.

CLEANING: Disconnect Monitor before cleaning. DO NOT immerse in
water. Use a dry cloth to keep Monitor free from dust. DO NOT spray with
cleaning products or solvents. Wipe Sensor Pad with a very slightly
damp cloth with an antiseptic or mild detergent.
OBJECT AND LIQUID ENTRY: Care should be taken so that objects do
not fall onto Monitor and that liquids are not spilled into either Monitor
or Sensor Pad through its openings.
NON-USE PERIODS: When not using monitor for long periods, remove
the batteries from Monitor.
4
®
MONITOR

Publicidad

Tabla de contenido
loading

Tabla de contenido