Important Remarks - Cardin Elettronica HL Serie Manual Del Usario

Ocultar thumbs Ver también para HL Serie:
Tabla de contenido

Publicidad

IMPORTANT REMARkS

TO REDUCE THE RISk OF SEVERE INJURY OR DEATH READ THE FOLLOWING REMARkS CARE-
FULLY BEFORE PROCEEDING WITH THE INSTALLATION. PAY PARTICULAR ATTENTION TO ALL
THE PARAGRAPHS MARkED WITH THE SYMBOL
TIONS COULD COMPROMISE THE CORRECT WORkING ORDER OF THE SYSTEM.
• These instructions are aimed at professionally qualified "INSTALLERS
OF ELECTRICAL EQUIPMENT" and must respect the local standards
and regulations in force. All materials used must be approved and
must suit the environment in which the installation is situated.
• All maintenance operations must be carried out by professionally
qualified technicians. Before carrying out any cleaning or maintenance
operations make sure the power is disconnected at the mains.
• This appliance must be used exclusively for the purpose for which
it has been made. "i.e. for the automation of one or two hinged
gates". The appliance may be used to operate hinged gates and
doors, with gate leaves up to 3 m in length and a maximum weight
of 350 kg.
• The unit may be fitted both to the right and to the left of the pas-
sageway.
• This product and all its relative components has been designed and
manufactured by Cardin Elettronica who have verified that the product
conforms in every aspect to the safety standards in force.
Any non authorised modifications are to be considered improper and
therefore dangerous.
The manufacturer accepts no liability for situations arising from the
use of an electrical installation which does not conform to the local
standards and regulations in force and in particular when the earthing
circuit is not efficient.
IMPORTANT! The geared motor is not fitted with a torque limiter.
Only use an electronic programmer which has a torque limiter
with maximum force at the head of the gate equal to 50 N.
IMPORTANT SAFETY INSTRUCTIONS
It is the responsibility of the installer to make sure that the following
public safety conditions are satisfied:
1) Ensure that the gate operating installation is far enough away from
the main road to eliminate possible traffic disruptions.
2) The operator must be installed on the inside of the property and not
on the public side of the gate. The gates must not swing outwards
onto a public area.
3) The gate operator is designed for use on gates through which vehicles
are passing. Pedestrians should use a separate entrance.
4) The gate must be in full view when it is operating therefore controls
must be situated in a position where the operator can see the gate
at all times.
5) At least two warning signs (similar to the example
on the right) should be placed, where they can be
easily seen by the public, in the area of the system
of automatic operation. One inside the property
and one on the public side of the installation.
These signs must be indelible and not hidden by
any objects (such as tree branches, decorative
fencing etc.).
6) Make sure that the end-user is aware that children and/or pets must
not be allowed to play within the area of a gate installation. If possible
include this in the warning signs.
7) Whenever a fully open gate leaf comes within at least 500 mm of a
fixed structure the space must be protected by an anticrush buffer
(fig. 1, detail 11).
8) A correct earth connection is fundamental in order to guarantee the
electrical safety of the machine
9) If you have any questions about the safety of the gate operating
system, do not install the operator. Contact your dealer for assist-
ance.
IMPORTANT REMARkS
. NOT READING THESE IMPORTANT INSTRUC-
TECHNICAL DESCRIPTION
800/HL2524SB Irreversible geared motor, maximum opening 0°.
806/HLCF
800/HL824SB Irreversible geared motor, gate opening 8°-360°.
806/HLCF8
• Single piece geared reduction unit;
- 24 Vdc drive motor with an incorporated overload protector and a
permanently lubricated reversible reduction unit mounted on a cast iron
stator;
- rubber sealing gasket;
- key operated manual release mechanism;
• Embedding case in hot rolled zinc-plated steel
- release unit housing in pressed aluminium
• Transmission levers in zinc-plated steel
- gate fastening bracket in zinc-plated steel.
INSTALLATION INSTRUCTIONS
The appliance is not suitable for continuous operation and must be contained
within the value stipulated (see technical data on page 20).
The minimum controls which may be installed are OPEN-STOP-CLOSE,
these controls must be installed in a location not accessible to children.
Before starting with the installation of the system check that the structure
which is to be automated is in good working order and respects the local
standards and regulations in force.
To this end make sure that the gate is sufficiently rigid (if necessary reinforce
the structure) and that the hinges turn easily.
You are advised to grease all the moving parts using lubricants which maintain
unaltered friction characteristics over a period of time and are suitable for
temperatures of -20 to +70°C.
• Check the safety measures between the fixed and moving parts:
- a minimum space of 30 mm must always be left along the entire dis-
tance between the gate and the support column measured throughout
the entire opening angle of the gate.
- make sure that the space between the bottom of the gate and the
pavement never exceeds 30 mm throughout the entire opening angle
of the gate.
• The surface of the gate must not feature openings which allow a person's
hand or foot to pass through.
• Check the exact positioning of the pivots and hinges, and their good
working order (the upper and lower hinges/pivots must be aligned on
the same axis).
• Work out the run of the cables according to the command and control
devices fitted and make sure the system conforms to the local standard
WARNING
and regulations in force (see installation example fig.1 pag. 2).
AUTOMATIC OPENING
kEEP CLEAR
• Check that the appliance is suitable for the size, weight and duty cycle
of the gate to which it is to be applied (see duty cycle on page 20).
FITTING THE UNIT
- Choose the ideal position for the foundation case according to the open-
CHILDREN OR PETS MUST NOT
BE ALLOWED TO PLAY ON OR
ing angle (90°-0°-80° fig. 5) and the position of the gate pivot.
NEAR THE INSTALLATION
- Place a mechanical travel buffer in the closing direction.
- Dig the foundation hole "A" (fig. 6) sufficiently large to house the founda-
tion case and run a drain channel up to the hole "B".
- Run the channelling for the cables up to the hole "C".
- Insert the six round headed screws "E" into the holes on the bottom of
the case and fasten down using the supplied nuts and washers.
- Place the foundation case in the hole with the pin perpendicular to the
upper gate pivot "D", cover the case in concrete and check that it is in
square and that the upper edge protrudes by at least 3 mm from the
ground.
- Remove the nuts and washers used to fasten down the round headed

IMPORTANT REMARkS
Embedding case in zinc plated steel with transmission
lever for 0°
Embedding case in zinc-plated steel with accessories for
gate opening 0°-360°

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Hl2524sbHl1824sbHlcf1Hlcf18

Tabla de contenido