1
GM.or.IM.Series
Flow.Meter
(Reed.Switch.Pickup)
2
*.Optional.to.use.HL-HF.IN.
1....Supply.(+)
2....Signal
GM.or.IM.Series
Flow.Meter
3....Common.(–)
(Hall.Effect.Pickup)
6
W I R I N G D I A G R A M 6
— 4-20 mA or 0-20 mA Output —
Customer Equipment with Built-in Power Supply
Input: Reed Switch
Output: Customer Equipment, 0-20 mA Sensing, Built-in Loop Power Supply
INPUTS
*.HL-LF.IN
Local.Com
W I R I N G D I A G R A M 7
— 4-20 mA or 0-2 0 mA Output —
Customer Equipment With Built-in Power Supply
Input: Hall Effect
Output: Customer Equipment, 0-20 mA Sensing, Built-in Loop Power Supply
HE.Power.Supply
4.5.-.24.VDC
(+)
(–)
INPUTS
HL-HF.IN
Local.Com
OUTPUTS
Loop.(+)
(current)
GPI.4-20.mA
Transmitter
Loop.(–)
(current)
*
OUTPUTS
Loop.(+)
(current)
GPI.4-20.mA
Transmitter
Loop.(–)
(current)
CAUTION:. When.reassembling.the.faceplate,.make.sure.that.the.enclosure.
seal.is.not.crimped.or.twisted..Do.not.over-tighten.corner.screws.
(hand.tighten.only)..Faceplate.can.be.rotated.90°.
Customer
Equipment
Min.. V.=.8.5.
Max..V.=.35
CAUTION:. When. reassembling. the. faceplate,.
make.sure.that.the.enclosure.seal.is.not.
crimped.or.twisted..Do.not.over-tighten.
corner.screws.(hand.tighten.only)..Face-
plate.can.be.rotated.90°.
Customer
Equipment
Min.. V.=.8.5.
Max..V.=.35