GVMAX HD
Heavy Duty Communicating Vacuum Pumps
Model GVMAXHD__V: vacuum pump with NO vacuum control and NC blow-off
In the event of power failure, vacuum is still generated: object is held in
place fail-safe.
In the event of compressed air failure, the vacuum is no longer
maintained.
NO vacuum solenoid valve
NC blow-off control solenoid valve
Blow-off controlled by external signal
Model GVMAXHD__L: vacuum pump with pulse-triggered bistable
vacuum control and NC blow-off (patented system)
In the event of power failure, the vacuum pump maintains its
previous state.
More specifically, one of the following two scenarios will take place
should this occur:
- During vacuum generation, the vacuum is maintained
fail-safe
- During blow-off or when the pump is off, the pump remains "Off"
Vacuum control is automatically stopped when the blow-off command is activated.
The vacuum can only be stopped with the blow-off command.
In the event of compressed air failure, the vacuum is no longer maintained.
Pulse-triggered bistable vacuum control solenoid valve (50 ms min.)
NC blow-off control solenoid valve
Blow-off controlled by external signal
5. CONNECTIONS
5.1 Pressure supply connection
COMPRESSED AIR OR VACUUM NETWORKS:
Wear safety goggles
Make sure all fittings and tubes are tightened securely
Tube ends must be fastened to avoid any risk of being pulled off in the event of accidental
breakage
- Non-lubricated air, filtered to 5 microns, according to
standard ISO 8573-1:2010 [3:4:4]
- Optimal dynamic pressure:
• 5 bar for dia. 2.5 mm nozzle
• 5.5 bar for dia. 3.0 mm nozzle
5.1.1 Standalone modules
- Compressed air connection through a G3/8"-F port
(mark
on pneumatic socket).
www.coval.com
SIMPLIFIED OPERATING INSTRUCTIONS
-8-
EN
NO
LATCH NO
P