Electrical connections: IZAR with encoder, VIVO-D102(M) board
STOP CABLE CONNECTOR: connect to the release switch (in the models with encoder and release). In the models
without unlocking, make an electrical bridge.
G1
Blue (motor)
G2
Red (motor)
P14 (GND) Mesh (encoder mesh) (–)
P15 (SNG1) Green (encoder signal) (S)
P13 (V+)
Brown (encoder power supply) (+)
Electrical connections: IZAR with limit switches, VIVO-D103 and ADB30 boards
STOP
C.T.
S.G.
DLG
Adjust the limit switches by turning wheels A and B, having previously removed the guide [C].
8
D102: 230Vac/ 50Hz
D102M: 125Vac/ 60Hz
LLAVE
COM
LLHP
COM
FOT
LG
LG
24Vac
AUX
- BATERÍA
(24Vac)
+ 12V
Check turning direction using the mini-pushbuttons ST1 (close) and ST2
(open), having first placed DIP1, DIP2 and DIP3 in OFF. If the turning
direction of the operator is not correct, interchange the cables connected
to the cable connectors
Ensure that the limit switches are connected correctly. If they are
not, the motor will continue to operate until wheel A or B reaches the
C
stopper, thus breaking the mechanism. Carry out the check using ST1
(close) and ST2 (open), having previously placed DIP1, DIP2 and DIP3 in
OFF.
M
ST1
SEMAFORO
DIP1
DIP2
DIP3
OFF
ON
ST2
|
(VCC).
M
TRAFO
MOTOR
G1
M
G2
GND
P14
SNG1
P15
V+
P13
ENCODER
P186Z
ANTENA
RADIO
DEST.
P186W