Watts IntelliFlow A2C-M1 Manual Del Usuario página 2

Válvula de cierre automático para lavadora
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Installing the A2C-M1 IntelliFlow
WARNING
!
Power MUST be off during installation or servicing of
the valve!
Do not plug valve into supply circuit until completion of
assembly.
NOTICE
For Vertical Installation Only!
1. Shut off electrical power supply.
2. Shut off both hot and cold water supply lines.
3. If retrofitting to an existing installation, disconnect the wash-
ing machine hoses from the existing shutoff valve(s).
4. Loosen the two (2) adapter nuts and remove both adapters
from IntelliFlow
valve body.
®
5. Place adapter nuts over piping prior to soldering adapters.
6. Solder adapters onto piping.
NOTICE
Piping must be 2
" on center (Figure 3).
3
8
7. Place O-rings on adapter grooves (Figure 3A).
8. Align and slip the valve body over adapters. Tighten adapter
nuts.
NOTICE
Do not over-tighten nuts.
To avoid cross threading, check thread alignment.
9. Connect the washing machine hoses to the IntelliFlow
hot and cold water outlets.
10. Plug the washing machine into the IntelliFlow
NOTICE
Appliance current rating must not exceed 15 amps.
11. Plug the IntelliFlow
's power cord into a house electrical
®
receptacle (Figure 4).
NOTICE
The IntelliFlow
requires a 120VAC, 60Hz, 15 amp ground-fault
®
protected receptacle.*
12. Install Leak Sensor
NOTICE
The IntelliFlow
will detect any current flow to the washing
®
machine when the washing machine is off. During startup or
at any time during troubleshooting, the IntelliFlow valve can be
reset to OFF condition by unplugging and reinstalling the leak
sensor.
13. Turn on both hot and cold water supply lines, and check for leaks.
14. If there are no leaks, turn on the electrical power. Installation
of the A2C-M1 IntelliFlow
*Ground Fault Interrupter – A GFI circuit is not required
for proper operation of the IntelliFlow
recommended as a safety device.
NOTICE
Use of the Watts Automatic Washing Machine Valve outlet
for appliances other than a washing machine is not recom-
mended and voids the warranty.
's electrical outlet.
®
®
is now complete.
®
, but is strongly
®
O-Ring
®
's
NOTICE
Do not plug valve into electrical supply circuit until you
have completed installing the unit and reconnecting the
water supply lines.
2
2
1
"
2
Figure 3
Adapter Nut
Adapter
Water Supply Piping
Figure 3A
Watts
A2C-M1
Washer
Figure 4
Power supply
ground fault
protected
Water supply

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Intelliflow a2c-wb-m1

Tabla de contenido