OVEN TYPE DESCRIPTION
II.
Power Supply
Check the nameplate for voltage rating.
Type 1-120V ovens utilize a preset (fixed) thermostat, providing
a 300 °F (149°C) average stabilized load temperature. These
units are designed to run on either AC or DC voltage.
Type 1-240V ovens utilize a preset (fixed) thermostat, providing
a 300 °F (149°C) average stabilized load temperature. These
units are designed to run on AC voltage only.
Power Cords
The ovens are supplied with a female IEC 320 locking power
inlet. This inlet accepts a male IEC 320 locking power cord.
Type 1-120V units are supplied with a three blade, grounded,
North American cord. When connected to a properly grounded
receptacle, these ovens meet the nationally recognized
standard for which they are marked.
Type 1-240V units must be used with a three blade, grounded
power supply cord (not provided). One side must be configured
with the IEC 320 male end.
available for the other end, including North American, European,
etc.
** CAUTION **
To provide continued protection against risk
of electrical shock, power cord must be
connected to a properly grounded outlet.*
* GFI recommended
8711 West Port Avenue • Milwaukee, WI 53224 USA • Phone (414) 973-3400 • Fax (414) 973-3275
Optional configurations are
www.phx-international.com • info@phx-international.com
Electrode Storage
Type 1 series ovens are not airtight and electrodes stored
within will start absorbing ambient moisture as soon as the
oven cools. We recommend removal of electrodes at shift end
and storage of same consumables in suitable larger holding
ovens until reissued.
These ovens are not to be used for re-baking or reconditioning
contaminated electrodes.
electrodes in 100% usable condition and to maintain that
condition until consumed at the job site. For optimum
stabilization, oven should be hot when loaded and kept "on
line" as long as electrodes are being stored.
Guide to Storage
In the absence of detailed storage information from your
electrode manufacturer, the "Guide To Electrode and Flux
Stabilization" (see last page of operators manual) may be used
as an indication of approximate temperatures. (A laminated
version and poster size version is available by contacting
Phoenix International, Inc.) For specific information involving
critical operations be sure to contact your electrode manufacturer
for complete information.
Repair - Spare Parts
These instructions contain wiring diagrams and a repair parts
list for your oven. For critical welding operations requiring
continuous holding, we would suggest carrying all of the parts
listed in the "Suggested Spare Parts Section V" of these
instructions.
** CAUTION **
Unit not to be exposed to rain or moisture.
Store only in dry location.
They are designed to accept
N5610459B-3