Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Installation assembly schematic is based on suggested materials. Installation assembly of this filtration system can be
modified by using various adapters.
Parts and Materials Included:
1) Filter Head
2) Filter Cartridge — AP902 includes AP910R, AP903 includes AP917HD and AP904 includes AP917HD-S
3) Bracket
Tools and Materials Required (not included):
Gather the required tools before starting installation.
Read and follow the instructions provided with any tools listed here.
A) Pipe Cutter
B) Two 1" Sweat connections
C) 2" Ball Valve (Sweat Type)
(qty 3 if bypass installed, qty 2 if no bypass)
D) Plumbers Tape
E) Adjustable Wrench
F) Torch (not shown)
G) Plumbing Solder (not shown)
H) Plumbing Flux (not shown)
NOTE: Additional plumbing supplies may
be required for optional bypass installation
To reduce the risk associated with property damage due to water leakage:
• Installation and Use MUST comply with all state and local plumbing codes.
City Water Installation
Well Water Installation
Pump

GETTING STARTED

A
B
C
CAUTION
Master
Shut-Off
Valve
0
90
90
10
10
3000
3000
300
300
Bad
Badger Meter
er Meter
80
80
2700
2700
600
600
20
20
Model
Model
BRP
BRP
2400
2400
70
70
Gallons
Gallons
30
30
2100
2100
0 0 0 0 6 9
1200
1200
1800
1800
1600
1600
40
40
50
50
Water
Meter
Master
Shut-Off
Valve
Pressure
Tank
Figure 1
D
E
Optional
Bypass Assembly
(recommended)
To Household
Plumbing
Optional
Bypass Assembly
(recommended)
To Household
Plumbing