•
Production date
Production code fi lter head – example: H 8252 11882
8
Production year, here: 2008
25
Production week, here: calendar week 25
2
Production day from Monday (1) to Friday (5), here: Tuesday
11882
Consecutive identifi cation number
Production code fi lter cartridge – example: B8252080010
8
Production year, here: 2008
25
Production week, here: calendar week 25
2
Production day from Monday (1) to Friday (5), here: Tuesday
08
Number of the mix variant, here: No. 8
0010
consecutive number of the fi lter cartridge, here the tenth cartridge; reset when the day changes
3.5 Technical Safety Assembly Instructions
•
The terminal device operated with the fi lter must be free of limescale prior to installation.
•
Protect the fi lter system from sunlight and mechanical damage. Do not assemble near sources
of heat and open fl ames.
•
A stop valve must be installed before the fi lter system intake hose.
•
If the water pressure is greater than 8.6 bar, a pressure reducer must be installed in front of the
fi lter system.
•
The fi lter head may be connected to the mains only with a non-return valve according to
EN 13959 or higher quality protection against return fl ows (see Chapter 10).
•
No copper pipes and no galvanised or nickel-plated pipes/connectors may be installed between
the water fi lter and consumer. The use of BRITA hose sets is recommended here. When choos-
ing the material for parts that come into contact with water after the BRITA fi lter system it must
be remembered that, due to the process, decarbonised water contains free carbon dioxide.
•
All parts must be installed in accordance with the country-specifi c guidelines on the installation
of drinking water facilities.
•
For erection and operation of the fi lter system, the BG rules "Working in Kitchens" of the spe-
cialist committee "Foods" of the BGZ (BGR111) must be observed.
4 Installation
Caution: Prior to installation, read the Technical Data (Chapter 9) and the Operating and Safety
!
Information (Chapter 3). After storage and transport below 0°C the product must be stored in the
open original packaging for at least 24 hours at the stated ambient temperatures (Chapter 9) for
operation.
4.1 Assembling the Filter Head, Water Connection
Caution: Ensure that the locking handle on the head is open.
!
•
Close water intake and switch off power supply to the terminal equipment.
A
•
Fit the wall mount
Caution: During assembly, note the installation dimensions, bending radii of the
!
B
hoses and dimensions of the accessories (e.g. BRITA FlowMeter). The system can be
operated vertically and horizontally. When using the wall mount, install vertically only!
•
Fit the hoses at the water inlet "IN"
C
G3/8" connections use fl at seals and with John Guest connections use hoses with an
8 mm diameter.
•
Caution: The max. tightening torque at the G3/8" connections must not exceed
!
14 Nm! Only hose connections with fl at seals may be used because hoses with conical
screw connections damage the connections of the fi lter head and invalidate any guaran-
tee claims! Only hoses that comply with DVGW-W 543 may be used for connection to
the device. The use of BRITA hose sets (Chapter 10) is recommended.
12
at the intended position.
5
and outlet "OUT"
4
of the fi lter head
. With
3
1