3.4 Wiring the Power Pack to Power Source

When using electrical products, basic precautions should always be followed, including the following:
DANGER: RISK OF ELECTRIC SHOCK WHICH CAN RESULT IN SERIOUS INJURY OR DEATH. Before
attempting installation or service, ensure that all power to the device is disconnected/turned off at the circuit
breaker. Connect only to a circuit protected by a ground-fault circuit-interrupter (GFCI).
Grounding is required. The unit should be installed by a qualifi ed service representative and should be
properly grounded and bonded (See Section 3.5, Bonding).
To avoid property damage, serious injury or death, never use the chassis backplate of the power pack to
ground any other equipment.
Install to permit access for servicing.
Please read all cautions and safety instructions in the Important Safety Instructions section. Before
attempting any electrical wiring, be sure to read and follow safety instructions. Wiring should only be
attempted by a qualifi ed professional.
1. Wire power pack to pool pump power source using 3.3 mm
pack to the LOAD side of a pump or the LOAD side of the pool pump timer relay so that the chlorinator can only
come on when the pool pump comes on (see Figure 18).
2. Attach the third wire (ground) from the electrical panel to the ground point inside the power pack. Additionally,
applicable local and/or National installation codes may require the equipment to be properly bonded to other pool
equipment or to a bonding grid. Bonding per Section 3.5 must also be accomplished to ensure personal safety and
safety of equipment.

3.5 Bonding

The National Electric Code (NEC) requires pool equipment to be bonded to each other. Check your local codes to
determine if the NEC and/or other local installation codes are enforced by the Authority Having Jurisdiction (AHJ).
A solid, copper 8.37 mm
bonding connection that is acceptable to the local AHJ. Refer to your locally enforced codes for the acceptable
bonding wire gauge. Attach the bonding point located on the bottom of the chassis backplate to a common bonding
point. Do not use the power pack as the common bonding point. Each piece of non-related pool equipment requiring
a ground should also be bonded to the common, approved bonding point. There should be one bonding connection
to the power pack. In Canada, the Canadian Electrical Code (CEC) dictates that the bonding conductor be, minimum
13.3 mm
(6 AWG).
2
Figure 18.

240 VAC or 120 VAC Wiring Diagram

(8 AWG) wire is recommended, per the NEC, for bonding the power pack to a permanent
2
Use Copper Conductors Only – Rated for 90°C Minimum
POOL PUMP TIMER
CIRCUIT BREAKER
PANEL
240 VAC or
120 VAC
50/60 Hz
LINE 1
3 wire
LINE 2
GROUND
Pool Pump
TO EARTH
BONDING POINT
WARNING
(12 AWG) insulated wire and conduit. Wire the power
2
12
RED
9
3
BLK
TO EI™ CELL
6
BLUE
BLK
TO FAN
RED
GRN
OPTIONAL
RED
CONNECTION
TO AQUALINK® RS
YEL
OR PDA
BLK
RIBBON CABLE
FROM CONTROL PCB
GROUND (CHASSIS)
LOAD 1
WHT
LOAD 2
BLK
TO EARTH
BONDING POINT
*The Power PCB auto-detects voltage

Power PCB*

Factory Wired for
240 VAC or 120 VAC ~
RED
BLK
BLUE
0V
NOT USED
BLK
RED
NOT USED
0V
POS
B
A
NOT USED
Line 2
NEUTRAL
NOT USED
Pump
Line 1
ACT
Page 13