7. WARNINGS
•
NOTE The outlet must not be mounted below the water line.
•
This pump is not suitable for pumping flammable liquids, diesel,
chemicals etc. Suitable for bilge water only.
•
NOTE: Bilge pump capacities may not be sufficient to prevent
flooding from rapid accumulation of water due to storms, rough weather and/ or
rapid leaks created by hull damage and or unsafe navigational conditions.
•
With all applications, it is important that a system of safe working practice is
applied to installation, use and maintenance. In order to securely fasten the unit,
ensure that the mounting surface is a minimum thickness of 19mm (3/4") (when
fitted with the screws supplied).
•
NOTE Do not screw directly to the hull. This pump must be mounted on a
bulkhead or on an additional board.
•
WARNING: Fire hazard. Wiring must comply with applicable electrical standards
and include a properly rated fuse or circuit breaker. Improper wiring can cause a
fire resulting in injury or death. Switch off the power while making connections.
Suggested wiring information is given as a guide only. For full information, refer to the
USCG, ABYC and ISO regulations for marine applications and wiring gauges,
connectors and fuse protection.
8. PARTS LIST
Qty 1
Orca Auto 1300 Pump
9. INSTALLATION
NOTE: Incorrect installation will invalidate warranty
Preparation - Always disconnect power sources before installation.
9.i Location
•
Choose a position to mount the pump that is dry and away from standing water
and is free from obstacles.
•
Mount in a position with the shortest possible pipe run lengths.
9.ii Mounting Instructions
•
To remove pump body, place hand over body,
depress locking tabs (eyes) and lift body from
strainer base (Figure 1). NOTE: Motor will be
removed with body
•
Use base as template to mark 3 mounting holes
in mounting pad.
•
Drill 1/8" (3mm) pilot holes. NOTE:
do not drill through hull; ensure that
the Orca is mounted securely to
additional board or bulkhead.
•
Use 25mm (1") or 28mm (1 1/8")
smooth bore reinforced hose to
connect to the strainer with hose
clips.
Qty 1
Screw Kit
Figure 1 -
Removing
base
Press
both
locking
tabs to
release
cover
Figure 2 -
Hose must rise upwards
Mounting
with NO DIPS
instructions
Skin Fittings
Outlet 12"
(305mm)
minimum
above the
water line
Suitable Mounting Pad