TFA No. 30.5010 Anleit_09_19
KLIMA GUARD
– Digital Thermo-Hygrometer
• Now press SET button again. ALARM appears and °C is flashing. Press ▲
or ▼ button to select the parameter for the alarm: °C = temperature, % =
humidity, °C Td = dew point, °C Tw = wet bulb temperature. Press SET but-
ton to confirm the alarm type.
• Press MODE button three times.
limit is activated). Press SET button and the value is flashing. Press ▲ but-
ton to advance and ▼ to decrease the lower alarm value. Hold the buttons
for a fast run. Press MODE button again.
alarm limit is activated). Set the high alarm limit in the same manner.
• Press MODE button to get out of alarm value set mode. Now the product is
ready to operate with alarm feature.
• When the measured temperature meets the set values, the alarm light on
the top of the instrument will flash and the buzzer will sound for one
minute. To stop the buzzer, press any button. The LED will still be on since
the alarm triggering condition did not change.
• If the high alarm value is lower than the low alarm value then the alarm is
activated when the measured values are within the two adjusted alarm
values.
Positioning and fixing
A circular opening is provided on the rear-side of the unit for hanging on the
wall. To place the unit in the standing position use the foot supplied with the
unit. Since the humidity level within rooms can vary greatly according to the
location, mount the unit so that it will monitor the conditions in a location
likely to be subject to the most problems.
Care and maintenance
• Clean it with a soft damp cloth. Do not use solvents or scouring agents.
Protect from moisture.
• Remove the batteries, if you do not use the product for a long period of
time.
• Keep the instrument in a dry place.
14
13.09.2019
11:46 Uhr
Seite 8
ALARM appears (when the low alarm
ALARM appears (when the high
KLIMA GUARD
– Digital Thermo-Hygrometer
Battery replacement
• Remove the stand. Open the battery compartment and insert two new bat-
teries 1.5 V AAA. Ensure batteries polarities are correct. Close the battery
compartment.
Troubleshooting
Problems
Solution
➜ Ensure batteries polarity are correct
No display
➜ Change the batteries
➜ Change the batteries
Incorrect display
If your device fails to work despite these measures contact the supplier from
whom you purchased it.
Waste disposal
This product has been manufactured using high-grade materials and compo-
nents which can be recycled and reused.
Never dispose of empty batteries and rechargeable batteries in
household waste.
As a consumer, you are legally required to take them to your
retail store or to appropriate collection sites depending on
national or local regulations in order to protect the environment.
The symbols for the heavy metals contained are:
Cd=cadmium, Hg=mercury, Pb=lead
This instrument is labelled in accordance with the EU Waste
Electrical and Electronic Equipment Directive (WEEE).
Please do not dispose of this instrument in household waste.
The user is obligated to take end-of-life devices to a designated
collection point for the disposal of electrical and electronic
equipment, in order to ensure environmentally-compatible dis-
posal.
15