Controls And Indicators; Temperature Controller; Main Power Switch; Ready" Pilot Light - Sagola PACK 6000X Manual De Instrucciones, Lista De Repuestos

Ocultar thumbs Ver también para PACK 6000X:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

8.1. TEMPERATURE
CONTROLLER
1.- Displays the temperature value. Is that captured
by the sensor on the equipment. (Program value)
2.- Temperature display indicator programmed.
3.- Displays the value of the programmed
temperature (nominal). (Set value)
4.- Self-tutoring pilot light. Blinks intermittently
during the self-tutoring process.
5.- Pilot lights indicating the activation of the
outputs of the controller.
C1-Is activated when there is air flow and the
resistance is heating the air. Turns on the red light.
C2-Not used.
6.- Pilot light indicating activation of Alarm 1.
Alarm 1
It's activated when the temperature of the
equipment reaches the value set, turning on pilot
"Ready". The triggering temperature setting is
determined in No.9 section.
7.- Pilot light indicating activation of Alarm 2.
Not used.
8.- Pilot light indicating activation of Alarm 3.
Not used.
9.- Push buttons to select the working temperature.
Also used to modify other values, at different
program levels.
10.- "SEL" push button to confirm the modified
values and access the different programming
levels.
5
2
1 0

8. CONTROLS AND INDICATORS

7
8
6
1
3
4
9
9
8.2. GENERAL START UP
SWITCH
- Position 1 "OFF"
Equipment completely switched off.
- Position 2 "ON"
All circuits activated.

8.3 "READY" PILOT LIGHT

The "Ready" (No.3) pilot light shows the user that
the equipment is ready to operate and at the
programmed working temperature.
Red led: Heating
Green led: Ready

8.4 TEMPERATURE SENSOR

Temperature sensor (No, 4) is located at the outlet
of the equipment.
It is not indicative of the temperature in the spray
gun or application tool, as there will be a loss of
temperature due to connections, hoses, etc...

8.5 FLOW METER

The flow meter (No. 5) is used to electrically disable
the resistance when the compressed air
consumption is insufficient for the proper operation
of the equipment. Therefore, when the spray gun
or application tool does not consume compressed
air, the resistance is disabled, once again becoming
enabled when consumption is resumed.
It is set at the factory to a value of approximately
150 litres / minute as the minimum flow for its
operation.
It is strictly forbidden to manipulate the flow switch
without prior consultation with SAGOLA S.A.
MANIPULATION OF THIS COMPONENT MAY PUT
THE PROPER OPERATION OF THE EQUIPMENT
Ignoring this warning may lead to the destruction
of the resistance and thus the voiding of the
guarantee that covers the equipment.
- 19 -
AT RISK
P2
P1