Instructions and user manual Device pH
Some important points :
The operation below is to be done at the beginning of each season during the commissioning of
the pool, and preferably every 3 or 4 months for the signal to remain the most correct possible.
The procedure is renewed in case of abnormal consumption of chemicals.
1)
electrode in the pH 7
solution, stir and leave
it
in
without touching the
electrode or the cable
The calibration of DEVICE PH is complete, it is now ready to measure the pH of your pool.

4.2 Pump priming

4.3 Settings

DEVICE PH functions
Unit of measure
Type of regulation
pH 7 calibration
Proportional regulation*
* Proportional : Dosing adjusted according to different cycles ON/OFF. At the approach of the set
point, the pump reduces its time of dosing.
Immerse
the
the
solution
When the device is off (OFF displayed), keep
pressed the ON/OFF button for a least 3 seconds to
Devicet priming.
Set point
Acid- reduce the pH by dosage of an acid (pH-)
2) After waiting at least one minute, the stabilized value is
displayed. Press CAL until the display shows CAL flashing then
release. Then the quality of the probe is briefly displayed.
Factory settings
pH
From pH7.0 to 7,6
To an accuracy more than 0.2 pH
Factory function
9
NOT065ENV02