Eco Control Connecting

As an option, Eco Control can be connected to the pump to control it.
• The control unit Eco Control (47673) is available as an accessory for Eco Expert pumps.
• If the pump is integrated in an EGC network, connecting Eco Control is not possible.
How to proceed:
 K
1. Remove the protection cap from EGC-IN.
2. Fit the plug connector of the cable and secure with the two screws (max. 2.0 Nm).
– Ensure that the rubber seal is clean and fits exactly.
– Replace the rubber seal if damaged.
Integrating the pump in the EGC network
 L
As an option, the pump can be integrated in an EGC network. In an EGC network, the InScenio FM-Master EGC or
InScenio EGC-Controller and all EGC-compatible devices are connected by means of a Connection Cable EGC. A ter-
minal resistor has to be fitted to the EGC-OUT of the last EGC compatible unit in order to terminate the network.
• The EGC connection cable is available as an accessory in the lengths 2.5 m (47038), 5 m (47039) and 10 m (47040).
• Ensure the correct connection.
How to proceed:
 K, L
1. Remove the protection cap from EGC-IN.
2. Fit the plug connector of the ECG connection cable and secure with the two screws (max. 2.0 Nm).
– Ensure that the rubber seal is clean and fits exactly.
– Replace the rubber seal if damaged.
3. Remove the protection cap from EGC-OUT, fit the terminal resistor and secure it with the two screws (max. 2.0 Nm)
or another EGC compatible unit.
– No Connection Cable EGC is connected to EGC-OUT on the last unit in the EGC network. The terminal resistor
has to be fitted to this EGC-OUT so that the EGC network is correctly terminated.
– The terminal resistor is included in the delivery scope of the InScenio FM-Master WLAN EGC.
N O T E
The device will be destroyed if water penetrates the EGC sockets.
• Close the EGC sockets with EGC plugs or a protection cap.
Commissioning/start-up
N O T E
The unit will be destroyed if it is operated with a dimmer. It contains sensitive electrical components.
• Do not connect the unit to a dimmable power supply.
When started up, the pump automatically performs a pre-programmed self-test (Environmental Function Control
(EFC)). The pump detects if it is running dry / blocked or submerged. The pump switches off automatically after ap-
prox. 90 seconds if it runs dry/is blocked. In the event of a malfunction, disconnect the power supply and "flood the
pump" or remove the obstacle. Afterwards, the unit can be restarted.
Switching on: Connect the unit to the mains. The unit switches on immediately.
Switching off: Disconnect the unit from the mains.
Seasonal Flow Control (SFC)
How to proceed:
 H
• Press and slide the switch.
– ON is indicated on the switch. The function is activated.
– ON is concealed on the switch. The function is deactivated.