- EN -
Commissioning/start-up
Caution! Do not damage the unit.
Protective measures: Never run the pump without water. Otherwise the pump will be destroyed.
Switching on the unit (J): Plug the power plug (30) of the transformer into the socket.
– The unit will start with program 1 (see chapter 'Control/Operation').
Switching off the unit (J): Pull the power plug (30) of the transformer.
Alignment of the Water Jet Lightning and setting the intensity of the water jet (L, M)
Prior to starting work, disconnect the power plugs of all units in the water (J)!
Adjusting the angle of inclination (L)
The diagram shows the shapes of the water jet at various angles of inclination of the Water Jet Lightning.
– Undo the fastening screw (34) at the unit foot (33).
– Swing the Water Jet Lightning to the desired angle of inclination.
– Tighten the fastening screw (34) at the unit foot (33).
Setting the water jet (M)
For the Water Jet Lightning, the intensity of the water jet can be set at the valves of the Y distributor (9).
– Turn the respective valve clockwise: to reduce the water flow.
– Turn the respective valve counter-clockwise: to increase the water flow.
Operation
4 pre-programmed water features can be selected with the manual transmitter.
After commissioning and with each new start of the unit, program 1 is automatically selected.
P0
P1
P2
P3
P4
Selecting the next program: Button 1
Selecting the previous program: Button 2
Note:
Note!
Depending on the degree of soiling in the water, the colours in the water jet may slightly deviate or change.
The manual transmitter contained in the scope of delivery is already taught in to the 12 V control box. Each further
manual transmitter has to be newly taught in for the 12 V control box.
Manual transmitter teach-in (K)
The 12 V control box (2) is equipped with a teach-in button (31) to be able to carry out the manual transmitter teach-in.
– Insert a pin (32) in the opening for the teach-in button (31).
– Actuate the teach-in button (31) using the pin (32) for approx. 1 sec.
– Press any button of the manual transmitter for at least 1 sec.
Deleting the manual transmitter (K)
– Actuate the teach-in button (31) using a pin (32) for at least 5 sec.
All manual transmitters saved in the 12 V control box (2) are deleted.
Note: A maximum of 10 manual transmitters can be set to the receiver. The manual transmitter has a maximum range
of 80 m. Obstacles between transmitter and receiver, a low battery in the manual transmitter, or electro-magnetic radia-
tion of electrical equipment will impair the range.
16
Unit off, stand-by mode
Constant water jet
White light activated
Constant water jet
Changing light colours
Pulsating water jet
White light activated
Pulsating water jet
Changing light colours
- From changing light colour, it is possible to set one colour only by pressing the buttons 1 and 2 simultaneously.
Changing light colour can be returned to by pressing the buttons 1 and 2 simultaneously again.
- If the Water Jet Lightning is switched by means of a timer, always program 1 is started.