Intended use
The „Water Jet Lightning", as termed in the following text, is a water feature fountain with LED lighting for permanent
installation. Only operate the unit with clean pond water at a water temperature of between +4 °C and +35 °C.
The unit is suitable for use in swimming ponds (Fig. E) if the national regulations valid for installers are met.
Installation
Attention! Dangerous electrical voltage!
Possible consequences: Death or severe injury.
– Install transformer and 12 V control box at a minimum safety distance of 2 m from the bank (E).
– Choose an installation place for the transformer and the 12 V control box that is splash-water protected.
Also protect the transformer and the 12 V control box against sun radiation (max. 40 °C).
Installation of the Water Jet Lightning (B, C, D)
Plan the installation of the Water Jet Lightning. When planning, take the cable and hose lengths into account!
Install the Water Jet Lightning horizontally on a firm base. The unit can be installed dry and in the water. When in-
stalled in the water, the upper section of the Water Jet Lightning must protrude out of the water by approx. 8 cm.
– Fasten the unit foot (12) on the base using 2 screws (13) (not included in our scope of delivery).
Pump installation and connection of the hoses (B, D)
Install the pump (4) as horizontally as possible. Raised installation can prevent the intake of dirt particles from the bot-
tom of the basin.
– Slightly loosen the union nut (14) at the Y distributor (15).
– Screw the reduction piece (16) on the pump (4) and insert the O-ring (17).
– Tighten the union nut (14) at the Y distributor (15).
– Screw the hose connection (19) on the Water Jet Lightning (1).
– Slide a hose clip (10) over the hose (6).
– Slide the hose (6) on the hose adapter (19) and secure with a hose clip (10).
– Connect the other end of the hose to the Y distributor (15) and secure with a hose clip (10).
Installing the 12 V control box
Variant 1 (F)
– Push the full length of the ground stake (8) into the ground at the desired position.
– Slide the 12 V control box (2) on the ground stake (8).
Variant 2 (G)
– Screw the 12 V control box (2) to the housing of the 12 V control box (2) on the base using 4 screws (21) (not
contained in the scope of delivery) through the screw gaps (22).
Setting up the transformer (H):
Place the transformer (5) close to the 12 V control box (2).
Note: Ensure that the cables are routed pull-relieved!
Electrical installation
Connect the Water Jet Lightning with the 12 V control box and the transformer (H, I)
– Insert the pump plug (23) from the plug and the plugs (24) of the two Water Jet Lightning units into the respective
sockets for the pump (25) and the Water Jet Lightning (26) at the 12 V control box (2).
– Screw-connect the plug (27) of the transformer connection cable on the secondary side to the socket (28) at the
rear of the 12 V control box (2) and screw tighten with the union nut (29).
– Place the protection hood (3) over the 12 V control box (2).
Note: If you only want to operate one of the two Water Jet Lightning systems, plug the jumper plug (49) into the second
free socket (26).