2. Rointe towel rails installation
2.1. Mounting instructions
Inside the packaging you will find a fixing kit. Please find the instructions below:
1. Choose the right part of the wall.
2. Place the mounting stencil on the wall, marking the places for the holes.
3. Remove the stencil and make the holes in the wall.
4. Insert the rawl plugs in the holes made.
5. Screw the plastic fastener to the wall with the 5.5 x 50 mm screw.
6. Screw the two brackets for supporting the product and the plastic fastener to the horizontal tube
of the product like in Figure 1 with the 8 x 26 mm screw.
7. Insert what you have assembled in Section 6 into the plastic piece. Fix well with the 5 x 12 mm screw.
8. Place the cover on the piece supporting the product.
NO.
ELEMENT
1
10 x 40 mm Rawl Plug
2
Bracket
3
5.5 x 50 mm Screw
4
5 x 12 mm Screw
5
Bracket Insert
6
Bracket Head
7
8 x 26 mm Screw
8
Cap
9
Product
2.2. Connecting instructions
Connection to the mains must be made observing the voltage stated on the product technical data label.
This product is designed to be permanently installed connected to fixed facilities. The product power
supply circuit must have an all-pole circuit breaker switch with a separation of at least 3 mm between
the contacts. The product must be installed, if possible, away from any source of draughts (windows,
doors) or any other thing which may affect its functioning. In this way, the temperature will not be
affected. Place any object which might prevent the air flow (furniture, armchairs) 50 cm away from the
front of the product.The product must never be installed immediately below a power point. The lower
part of the control panel must be placed at least 15 cm from the floor.
For any product, if the power cable is damaged, it must be replaced by a specific cable. The replacement
of the cable must be done by the maker, its after-sales service or qualified personnel. The technical
specifications of your product appear on the technical data label.
8
1
5