Air Regulator - Helvi PC 73 Manual De Uso Y Manutención

Equipo de corte por plasma inverter trifasico
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

FUNCTIONS
10
12
2
13
ON/FF Switch (1) on the back side – In the ON
position the machine is ready for normal operation.
All system control circuits are activated. OFF po-
sition deactivates control circuits.
Output Current Knob (2) - Adjusts the cutting
current supplied by the machine according to ap-
plication (thickness of material/speed).
DISPLAY (3)
views the set cutting current when unit is on, during
pilot arc time views the pilot arc current and during
cutting views the cutting current.
It views the air pressure (bar) once air drain knob (8)
is pushed and during air pressure adjustment (9).
GREEN LED (4)
Turns ON when input voltage is applied to the
machine.
YELLOW LED (5)
Turns ON when the thermal protection is activated.
18
3
11
8
4
9
14
YELLOW LED (6)
Turns on when the under-, overvoltage protection
is workin or when phase is missing.
RED LED (7)
Turns ON when pilot or cutting arc is initiated.
TORCH AIR PURGE BUTTON (8)
Allows to remove any condensation that may have
accumulated in the torch and leads while the sy-
stem was shut down and to get the pressure set
thru the air regulator (9) viewed on the display.

AIR REGULATOR (9)

Adjusts the input air pressure - pull outwards to
unlock. Note: push torch air purge button be-
fore acting on the air regulator to get the air
pressure displayed.
AMP LED (10)
when on it means that the display is viewing the
adjusted or the effective cutting current or the arc
current.