MEC-D / MEC-DMR / BHD
6.3
Maintenance
Routine maintenance of the unit can also be carried out by unspecialized personnel so long as the safety prescriptions indicated in
chapter 2 "Safety" are complied with.
Extraordinary maintenance and repairs may only be carried out by authorized specialized workshops.
Removal
GB
If the product must be disas
sembled, check the weight and stability of the various components as they are demounted (consult chapter 4 "Storage and handling").
Changing the oil in the gearbox
2) pour in the right quantity and type of new oil (consult the "Pumps table" in chapter 10 "Technical data");
3) use the oil dipstick to check that the quantity is correct;
4) strictly comply with the disposal rules and regulations in relation to the old oil in the receptacle, consigning it to an authorized disposal
organization (use services of the COBAT Consortia in Italy).
Replacing the packing gland
1) remove the packing adjuster screws and allow the packing to slide;
2) replace the seal material;
3) ATTENTION
adjust the gland packing by working evenly on both nuts in order to ensure a slight drip during operation;
4) restore the initial conditions.
6.4
Spare parts
The following data should be given when spare parts are ordered from Caprari S.p.A. or one of its Authorized After-Sales Centers:
1 - the complete code of the product;
2 - the data code and/or serial number and/or job number when applicable;
3 - the denomination and reference number of the part as indicated in the spare parts catalogue (available from authorized after-sales service
centres) or in the typical sections depicted in this manual;
4 - the required number of spare parts.
6.5
Inactivity
If the pump remains inactive in the system, make sure that the rotor is free to turn and that the hydraulics are primed before starting.
standstill.
In relation to the cooling circuit of the oil housing when installed, detach the longer pipe from the hydraulic part, taking care to prevent it from being
Consult chapter 4 "Storage and handling" for further instructions.
7

DISPOSAL AND DISMANTLING

When dismantling the product, the technician must proceed with the relative phases in strict compliance with the local rules and regulations
governing such activity.
8

WARRANTY

The general conditions of sale governing all products manufactured by Caprari S.p.A. are also valid for the product in question.
In particular, remember that one of the essential conditions for recognition of the warranty is compliance with all the individual instructions given
in the enclosed documentation and the best hydraulic and electrotechnical provisions, fundamental condition to ensure regular operation of the
product. Malfunction caused by wear and/or corrosion is not covered by the warranty.
Sales Service Centres.
Failure to comply with the instructions in the documentation supplied with the product shall void all forms of guarantee and shall relieve the
manufacturer from all responsibility in merit.