HOW TO USE A SOLDERING TIP AND A HOT
BLOW TIP
Hot air exhaust hole
Ignition vent
OPEN/CLOSE knob
CAUTION: Be sure the ignition vent knob is in backward
position. The vent knob and air exhaust hole must be posi-
tioned upward when tool is operated.
1. Set lever to "ON" position.
2. Ignite gas by means of a lighter at ignition vent.
3. Wait until inside of ignition vent is red.
4. Close the ognition vent holed by pushing knob forward. By clo-
sing the holes, the flame turns off and the mixture air/gas in
contact with the catalyser produces heat.
5. Control tio temperature by control lever.
6. To shut off, slide the gas main lever to postion "OFF" until it
clicks.
For temperature lower than position 1 push main lever to OFF and
re-open again after three seconds. This results in lower heat
generation of the catalyzer. If temperature is still too high, repeat
this procedure.
CAUTION: When using a soldering tip or a hot blow tip, hot air comes out from
the exhaust hole in the tip. Be sure to keep clear from the hole to avoid burns.
HOW TO USE THE TOOL AS TORCH
1. Remove tip and tip housing by untightening knurled screw.
2. Push vent knob forward; small round holes on the soldering
ejector will appear. Insert the accessory spanner in one of the
small holes and untight the soldering ejector. Remove ejector.
3. Mount torch ejector in the place of the removed soldering
ejector. Use accessory spanner to tighten.
4. Set vent knob in backward position.
5. Set control lever at 3. Gas OPEN/CLOSE main lever in position
"ON".
Never direct the flame nozzle at persons or look into the outlet.
Never bring inflammable objects, fluids or gases near the hot
soldering iron.
The soldering iron must not be operated without the nozzle.