Commissioning
Logic Assignments
1
2
2
1
3
3
5
4
4
ADDR
Status-LEDs
AS-i
FAULT
Safety Notes
Technical data
Electrical data as per AS-i
specification
Inputs
Mechanical data
Temperature range
Material
To start up the coupling module, carry out the following steps:
Step
Procedure
1
Set the address if you want to carry out addressing prior to installation.
2
Arrange the AS-i cable so that the wide edge is at the top (profile lug as desired).
3
Engage the coupling module in the mounting plate and secure with screws.
4
Set the address if you have not carried out step 1.
5
Connect the switching elements to the M12 sockets.
The following table shows the logic assignments for
Socket
Pin Assignments / Data Sheets / Function
1
Pin 1 and pin 2: acts on bits D0 and D1 = channel 1,
Pin 3 and pin 4: acts on bits D2 and D3 = channel 2, pin 5 not used.
2
Pin 1 and pin 2: acts on bits D2 and D3 = channel 2, pin 5 not used.
3
Not used
4
Not used
• If only one one-channel switch is to be connected, this must be assigned to channel 1. The
2nd channel must be jumpered. This can be performed via a wire jumper between PIN 3 and
PIN 4 at socket 1.
• Pin 3 of socket 1 is connected with pin 1 of socket 2, and pin 4 of socket 1 is connected with
pin 2 of socket 2! If both pairs of sockets are in use, the inputs are linked!
The following table shows the status - LEDs and their operating states:
AS-i / FAULT
Operating state
green
Communication OK
Off
No voltage present at AS-Interface-Chip
red permanent
Communication failed
red/yellow
Slave has address "0"
flashing
• Cover unused M12 sockets with screw plugs to obtain degree of protection IP 67.
• Degree of protection IP 67 is obtained after the coupling module is fixed on the mounting plate
with cable inserted.
• Sockets 3 and 4 are not to be opened.
• The PE plug tag (below) is not in use.
• Each code table may occur only once in one AS-i line connected to the safety monitor.
I/O configuration (hex)
ID code (hex)
ID1-code (Hex)
ID2-code (Hex)
Total current drain
Reverse polarity protection
Low signal range
High signal range
Degree of protection
Weight
Dimensions in mm (h x w x d)
Rated temperature
Ambient temperature
Storage temperature
Casing
Gasket
Screw, washer
ASKM1/2SE
0
B
F
F
≤ 45 mA
I
yes
contact open
contact closed
≥ 5 mA)
I
dynamic (I
in
peak
IP 67 (with mounting plate ASKM1-MP)
approx. 100 g
80 x 45 x 34
T
25 ˚C
u
T
-25 ˚C to 85 ˚C
a
T
-40 ˚C to 85 ˚C
s
PBT (Crastin)
TPE (thermoplastic K) in the casing
NBR for O-ring in the M12 sockets
Stainless steel V2A