R E A D A N D S AV E T H E S E I N S T R U C T I O N S
1.
Disconnect the power source previously brought to the hand dryer
location (see pre installation wiring).
2.
Remove the 2 cover mounting screws using the Tamper-Proof
Wrench supplied. Lift the cover to remove from base plate.
3.
If electrical wiring entry is to be made from the rear, remove the
appropriate pre-formed knockout on the base plate. If entry is to be
made from the bottom, knock out the pre-formed area on the cover
for your supply connection. A rigid conduit must be used for the
electrical wiring to the unit.
4.
Select the appropriate mounting height for the dryer (Table 1).
Select the recommended fastener (Table 2). There should be no
obstruction between the hand dryer and the floor. If mounting over
a countertop, distance form counter to dryer must be 15"
(381 mm) minimum.
CAUTION: Do not use the Base Plate as a guide when drilling.
Make sure no pipe work (gas, water, air) or any electrical cables or
wires are located directly behind the area to be drilled.
5.
Attach Base Plate at the four corners to a smooth wall. For most
secure installation, use 2 additional mounting holes as shown in
drawing. For non-HEPA units, remove Control Assembly to access
the right side mounting hole. For HEPA units, remove filter only to
access the right side mounting hole.

SIDE VIEW

TABLE 1
SUGGESTED MOUNTING HEIGHT
1
from floor to bottom of dryer:
Men
45" (114 cm)
Women
43" (109 cm)
Teenagers
41" (104 cm)
Small Children
35" (89 cm)
Accessible
37" (94 cm)
E X C E L D R Y E R , I N C
3 5 7 C H E S T N U T S T R E E T, E A S T L O N G M E A D O W , M A 0 1 0 2 8

INSTALLATION INSTRUCTIONS

1 . 8 0 0 . 2 5 5 . 9 2 3 5
E X C E L D R Y E R . C O M
6.
Identify the voltage of your dryer from the rating sticker of the unit.
Then connect to a dedicated branch circuit not exceeding 20 Amp.
7.
Secure electrical wiring to terminals as indicated by the schematic
affixed to blower housing. An identified ground connection point is
supplied on the Base Plate for your equipment ground wire. Dryers
should be installed per local code requirements.
8.
Carefully replace Cover using the 2 screws previously removed
in step 2. Restore power and test for proper operation. In multiple
installations, make sure the serial number marked on the inside
matches the cover number.
9.
It is highly recommended that a bead of silicone sealant be placed
around the outside of the cover at the wall to protect dryer from
internal corrosion caused by wash water and cleaning solutions.
10. Return Tamper-Proof Wrench to owner.
TABLE 2
MOUNTING HARDWARE
2
Recommended Fastener (not supplied):
Masonry Wall
½" Expansion Sleeve with ¼" Lag Bolt
Hollow Wall
¼" Wing Type Toggle Bolt
Wooden Wall
¼" Lag Screw With Washer
A D M I N @ E X C E L D R Y E R . C O M
FRONT VIEW
FACING WALL
1 1 / 2 0 1 7
2

Publicidad

loading

Este manual también es adecuado para:

Xleratoreco serieEx-bwEx-wEx-grEx-cEx-sb ... Mostrar todo