Descargar Imprimir esta página

Fulgor Milano CREATIVE CPH 401 ID X Manual Del Usaurio página 25

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 52
Error code
E/A
Hardware defect of
induction modul.
E/C
Configuration failure.
E/H
Fixed sensor value (test
function for T sensor on
inductor).
No functionality
Overvoltage on the switch
and no
mode power supply (jno
displaying
fuctionality).
E
A blinking "E" on each
cooking zone indicates, that
all configs will be.
E/2
Temperature limits are
(Error code
excessed.
different for
some UI)
E/3
Unsustable pot, e.g. lost of
the magnetic characteristics
because of temperature in
the bottom.
E/4
Unconfigured induction
modul (all induction modul
answer to UI, but any
element is related to the
effected cooking zone).
E/5
No communication between
UI and inducation modul.
E/6
Main power disturbace .
description
Defect hardware device
detected by the self
check of the modul.
2 cooking zone are
dedicated to the same
element of the UI.
Not enough
temperature change
(10K) within 5 min after
switch on the hob.
400V connection.
The user is in the
service menù, it's not
an error.
1. Pot or glas
temperature is to
2. NTC - electronik
temperature to high.
Pot creates on the
modul an improper
operating point which
can destroy devices,
e.g. IGBT.
Induction modul is not
configured.
No power supply of
induction modul
Mal cabeling or defect
of.
1. Failure in main power
frequency detection.
25
Possible causes
Exchange the modul.
1. Erase the actual
configuration manual with
service menù.
Systerm must cool down.
Disconnet and correct the
power line connection.
Manual configuration.
System must cool down.
1. the error is automaticly
cancelled after 8s and
the cooking zone can be
used again. In case of
further upcoming errors
the post have to be
changed.
2. the modul has to be
changed if the error
comes without an pot on
the cooking zone.
1. Delet the hob
configuration and activate
the manual configuration.
2. Start the UI service
menue to configure the
imduction modul.
3. If the listed points are
not succesful replace the
modul.
Check power and lin
connections is the
connention ok, replace
the modul.
Check main power
voltage and frequency,
if ok.
Error recovery
GB

Publicidad

loading

Este manual también es adecuado para:

Creative cph 402 id x