Briteq LD SMART DIM Manual De Instrucciones página 6

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

ENGLISH
OPERATION MANUAL
INSTALLATION
The LD-SMART DIM should be installed in a wall using a standard box 60x60 (ex: Legrand, Bticino,...)
Depending on the box, you can use two or four screws to fix the frame on the plastic box.
The front plastic cover clips on the metal frame.
CONNECTIONS
The LD-SMART DIM can be daisy chained with several other units on the same bus. The user can install
one unit in each zone, it will of course be easier to control the light fixtures in each zone.
The units must be daisy chained using CAT5 cable. Other cables are not suitable to interconnect them on
the data bus. The maximum length for the data bus is the same as the DMX standard (100m max). Each LD-
SMART DIM has one dmx output, so the user can connect locally the dmx projectors directly to the LD-
SMART DIM. The dmx projectors must be connected using a standard 3/5 wires dmx or a CAT5 cable up to
100m.
IMPORTANT: maximum number of controllers on the same bus is 8.
The DMX-output may not be daisy chained between several LD-SMART DIM.
It's an output only, the units can be damaged.
BRITEQ
4/44
LD-SMART DIM
®

Publicidad

Tabla de contenido
loading

Tabla de contenido