Descargar Imprimir esta página

Installation - Thetford SANICON TURBO 300 Manual De Instalación Y Propietario

Ocultar thumbs Ver también para SANICON TURBO 300:

Publicidad

Overview
Follow the instructions below to attach the SANICON® 300 to the
RV coach.
Read and understand the warnings listed in this docu-
AVISO
AVIS
!
!
!
!
NOTICE
ATTENTION
ATENCIÓN
CAUTION
DANGER
ment before you install, operate, or service this system. If
ATTENTION
ATTENTION
ATTENTION
you do not obey these warnings there is a risk of property
loss, injury, or electrocution. Do not make any changes to
this unit as this could result in property damage, injury, or
electrocution.
Thetford Corporation accepts no responsibility or liability for
damage to equipment, injury, or death that may result from the
system's improper installation, service, or operation.
Thetford Corporation recommends that plumbing and electrical
work be performed by a licensed tradesperson. Local permit
and code compliance is required.
Optional Materials (Not Provided)
Battery - 12 V
Wire & connectors for quick connection
Warnings and Cautions
Read and understand the warnings and cautions listed in this
document before you install or operate this unit.
Do not make any changes to this unit, as this could result
NOTICE
AVISO
AVIS
!
CAUTION
in property damage or injury.
Gray and black water tanks MUST BE COMPLETELY
FREE FROM DEBRIS before installing and operating the
pump. Failure to comply with this warning could result in
a voided product warranty and equipment failure.
The installation site of the pump MUST be able to support
a minimum of 30 pounds.
The pump is suitable for indoor and outdoor use, but
must be protected against water.
Questions?
If you have any questions or need assistance, please contact
Technical Support at 1-800-444-7210, available Monday through
Friday 8 a.m. to 6 p.m., Eastern Standard Time.
97571 Rev. C (07/10/2017)

Installation

General Guidelines
Gray water bypass can be achieved by plumbing the discharge
line in a manner that gravity can allow liquid to fl ow to the hose
with no upward plumbing.
AVISO
AVIS
!
NOTICE
CAUTION
Thermal Cut-Off Switch
Because SANICON® Turbo pumps are designed for intermittent
duty, the pump contains a thermal cut-off switch for your safety.
Typical run time is 15-20 minutes of operation before the thermal
shut-off switch turns the pump off. After 20 minutes, the thermal
cut-off switch will reset and allow the pump to run again.
■ If the pump is run immediately after a thermal reset, it will run
for approximately five - eight minutes.
■ If allowed to cool for several hours it will run the full 20 min-
utes.
Pump Performance
Performance varies with hose size and length:
®
SANICON
hose 1.5" x 21'
®
SANICON
hose 1.5" x 21'
®
SANICON
hose 1.5" x 21' w/
100' 3/4" garden hose
SANICON
®
hose 1.5" x 21' w/
100' 3/4" garden hose
®
SANICON
hose 1.5" x 21' w/ 50'
3/4" garden hose
Thermal cut-off will occur after 20 minutes. Refer to
i
"Thermal Cut-Off Switch" discussion.
2
It is important to plumb hose avoiding sharp
angles or bends during use or storage.
Hose
Height
& Length
9'
0
9'
0
0
SANICON
Flow
Minutes
Rate
to Empty
(gal/
100 Gal-
min)
lons
11.1
9
18.7
5
0.7
143
i
3.7
27
i
6.2
16
®
Turbo - Model 300