Installation, cont'd.
Connect Electrical
2A
K4
Ref.
Description
K1
Macerator Pump
K3
Macerator Switch
K4
35A Fuse/Breaker
2A
Battery
2B
Relay
2C
Thermal Cut-off Switch Over-Temperature Switch (90°C) nor-
mally closed
2D
Ground
Fig. 2 shows recommended wiring confi guration. Other wiring
confi gurations are possible based on your installation.
■
Pump requires a 12-VDC/35 AMP dedicated circuit with 35
AMP breaker or fuse between main bus or battery.
■
Wire size is dependent on distance between pump and
power source. Actual wire sizes should be calculated ac-
cording to installation.
Wire Gauge Size Chart
If Wire Gauge for distance from
source* is:
12 VOLTS - Install
* Distance measured assumes power
and ground wires.
Wire Size
■ Wire size is dependent on the distance between the pump and power source. Actual wire sizes should be calculated according
to installation.
■ Excess wire can be cut to length.
97571 Rev. C (07/10/2017)
Fig. 2
Pump Assembly
2B
85
86
0-18 feet
19-32 Feet
(Included)
10 Gauge
8 Gauge
Fig. 3
4
K3
K1
While the pump is turned on, make sure electrical
AVISO
AVIS
!
NOTICE
CAUTION
system by measuring voltage at motor; (must be
12V). Improper installation may cause damage to
motor or decrease pump effi ciency.
he positive and negative wires to prevent radio
Braid t
NOTICE
interference during operation.
33-50 feet
6 Gauge
2C
18G BLU
18G BLU
Included in product
Circuit Breaker
35 amp
®
Turbo - Model 300
SANICON
2D
2D