ENGLISH
DESCRIPTION:
PROJECTOR
1. FILTER FRAME: can be used for all kinds of optional
filters, like frost filters (to make the beam wider).
2. DOUBLE BRACKET: with knob to fasten the unit in
the desired position and a mounting hole to fix a
mounting hook. As it is a double bracket, it can also be
used as a floor stand.
3. MAINS cable: to power the unit.
4. DMX INPUT: 3pin male XLR-connector used to
connect the projector with the DMX controller or with
the previous unit in the DMX chain.
5. DMX OUTPUT: 3pin female XLR-connector used to
connect the projector with the next unit in the DMX
chain.
6. Fuse holder: always replace a damaged fuse with a
fuse of the same type and electrical specifications!
(250V 2A slow blow)
7. DISPLAY shows the various menus and the selected functions.
8. DOWN button: to lower the values shown on the display.
9. UP button: to increase the values shown on the display.
10. ENTER button: used to confirm your choice or to enter the setup mode of a function.
11. MODE button: used to browse the different functions in the menu
OVERHEAD RIGGING
Important: The installation must be carried out by qualified service personal only. Improper
installation can result in serious injuries and/or damage to property. Overhead rigging requires
extensive experience! Working load limits should be respected, certified installation materials
should be used, the installed device should be inspected regularly for safety.
Make sure the area below the installation place is free from unwanted persons during rigging, de-rigging
and servicing.
Locate the fixture in a well ventilated spot, far away from any flammable materials and/or liquids. The
fixture must be fixed at least 50cm from surrounding walls.
The device should be installed out of reach of people and outside areas where persons may walk by or be
seated.
Before rigging make sure that the installation area can hold a minimum point load of 10times the device's
weight.
Always use a certified safety cable that can hold 12times the weight of the device
when installing the unit. This secondary safety attachment should be installed in a way
that no part of the installation can drop more than 20cm if the main attachment fails.
The device should be well fixed; a free-swinging mounting is dangerous and may not
be considered!
Don't cover any ventilation openings as this may result in overheating.
The operator has to make sure that the safety-relating and machine-technical
installations are approved by an expert before using them for the first time. The installations should be
inspected every year by a skilled person to be sure that safety is still optimal.
BRITEQ
®
3/55
OPERATION MANUAL
BT-STAGEPAR 6in1