ENGLISH
DESCRIPTION:
1. FIXING HOLES: can be used to fix the projector to the ground,
wall or ceiling. Use adapted, non corroding, screws or bolts for
this.
2. MAINS INPUT: connect this power to the mains. If the projector
is used outside you MUST use a waterproof junction box. (our
"LDP-JUNCTION IP68" (order code: 5112) is perfect for this!)
3. DMX OUTPUT: this cable is used for DMX512 linking to the
next projector in the chain. Use good quality DMX-cable to
assure stable performance. If the projector is used outside you
MUST use a waterproof junction box. (our
(order code: 5112) is perfect for this!)
4. DMX INPUT: this cable is used for DMX512 linking coming from
a DMX-controller or from the previous projector in the chain.
Use good quality DMX-cable to assure stable performance. If
the projector is used outside you MUST use a waterproof
junction box. (our
perfect for this!)
5. TEMPERED GLASS: protection for the LEDs, make sure to
replace the glass while broken!
6. BRACKET: with 2 bolds on both sides to fasten the unit in the
desired vertical position.
7. LEDs: 4pcs RGB 3-color 3watt LEDs.
8. BRACKET BASE: with 2 bolds to fasten the unit in the desired
horizontal position.
9. ALUMINIUM BASE: contains all electronics and power supply.
OVERHEAD RIGGING
Important: The installation must be carried out by qualified service personal only. Improper
installation can result in serious injuries and/or damage to property. Overhead rigging requires
extensive experience! Working load limits should be respected, certified installation materials
should be used, the installed device should be inspected regularly for safety.
Make sure the area below the installation place is free from unwanted persons during rigging, de-rigging
and servicing.
Locate the fixture in a well ventilated spot, far away from any flammable materials and/or liquids. The
fixture must be fixed at least 50cm from surrounding walls.
The device should be installed out of reach of people and outside areas where persons may walk by or be
seated.
Before rigging make sure that the installation area can hold a minimum point load of 10times the device's
weight.
Always use a certified safety cable that can hold 12times the weight of the device when installing the unit.
This secondary safety attachment should be installed in a way that no part of the installation can drop
more than 20cm if the main attachment fails.
The device should be well fixed; a free-swinging mounting is dangerous and may not be considered!
Don't cover any ventilation openings as this may result in overheating.
The operator has to make sure that the safety-relating and machine-technical installations are approved by
an expert before using them for the first time. The installations should be inspected every year by a skilled
person to be sure that safety is still optimal.
BRITEQ
®
"LDP-JUNCTION IP68" (order code: 5112) is
(IF APPLICABLE)
"LDP-JUNCTION IP68"
3/44
USER MANUAL