Resistance Measurements; Diode Test; Capacitance Measurements - Southwire True RMS 14090T Instrucciones De Operación

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Operation cont.

Resistance Measurements

WARNING:
Never test resistance on a live circuit.
1. Set the rotary function switch to
the
position
2. Press the MODE
button until the
" " symbol appears on the LCD
display.
3. Insert the black test lead into the
COM input jack and the red test
lead into the
input jack.
4. Touch the test lead probes to the component
under test. If the component is installed in a circuit,
it is best to disconnect one side before testing to
eliminate interference with other devices.
5. Read the resistance in on the LCD display.
Continuity
WARNING:
Never test continuity on a live circuit.
1. Set the rotary function switch to
the
position.
2. Press the MODE
button until
the " " symbol appears on the
LCD display.
3. Insert the black test lead into the
COM input jack and the red test
lead into the
input jack.
4. Touch the test lead probes to the
device or wire under test.
5. A beeper will sound if the resistance is approximately
50 or less and the resistance value will be shown
on the LCD display.
LoZ mV AnF M k
AC+DC
0
10
20
30
40
50
60
AUTO HOLD REL PEAK MAX MIN AVG
LoZ mV AnF M k
AC+DC
0
10
20
AUTO HOLD REL PEAK MAX MIN AVG
LoZ mV AnF M k
AC+DC
0
10
20
30
40
50
60
AUTO HOLD REL PEAK MAX MIN AVG
LoZ mV AnF M k
AC+DC
0
10
20
AUTO HOLD REL PEAK MAX MIN AVG
13
Operation cont.

Diode Test

WARNING:
30
40
50
60
1. Set the rotary function switch to the
2. Press the MODE
appears on the LCD display.
3. Insert the black test lead into the COM input jack and
the red test lead into the
4. Touch the test lead probes to the diode under test.
5. Forward voltage will indicate
0.4 to 0.7 on the display. Reverse
voltage will indicate "OL". Shorted
devices will indicate near 0 and
an open device will indicate "OL"
in both polarities.

Capacitance Measurements

WARNING:
taking capacitance measurements.
30
40
50
60
1. Set the rotary function switch to
the
position
2. Insert the black test lead into the
COM input jack and the red test
lead into the
3. Touch the test lead probes to
the capacitor under test.
4. Read the capacitance value on the
LCD display. It may take up to a
minute to get a stable reading on
large capacitors.
Never test diodes in a live circuit.
position.
button until the " " symbol
input jack.
Red
Probe
Forward test
LoZ mV AnF M k
AC+DC
0
10
20
30
40
Safely discharge capacitors before
AUTO HOLD REL PEAK MAX MIN AVG
input jack.
14
LoZ mV AnF M k
AC+DC
0
10
20
30
40
50
60
AUTO HOLD REL PEAK MAX MIN AVG
Black
Black
Red
Probe Probe
Probe
Reverse test
50
60
LoZ mV AnF M k
AC+DC
0
10
20
30
40
50
60
AUTO HOLD REL PEAK MAX MIN AVG

Publicidad

Tabla de contenido
loading

Tabla de contenido