o o r r NPN-o o p p t t o o c c o o u u p p l l e e r r with open collector and open emitter
Switching power
U
at Ic = 15 mA
CEsat
U
at Ic = 5 mA
CEsat
A A u u x x i i l l i i a a r r y y p p o o w w e e r r s s u u p p p p l l y y o o u u t t p p u u t t f f o o r r m m e e a a s s u u r r i i n n g g t t r r a a n n s s d d u u c c e e r r / / s s e e n n s s o o r r
A A C C models
D D C C models
The auxiliary power supply is galvanically isolated from the inputs, outputs and
the interface.
2 2 . . 2 2 . . 4 4 I I n n t t e e r r f f a a c c e e
Available options
Baud rate
Address
Data format
Character format
The interface is galvanically isolated from the inputs, the auxiliary voltage and the supply
voltage.
2 2 . . 3 3 M M e e c c h h a a n n i i c c a a l l D D a a t t a a
Housing
Dimensions (W x H x D)
Panel cut-out (B x H)
Mounting depth
Weight
Protection
C C o o n n n n e e c c t t i i o o n n s s
Power supply and output:
Measurement and control input:
Interfaces:
C C l l e e a a n n i i n n g g : :
* only with interface option
2 2 . . 4 4 E E n n v v i i r r o o n n m m e e n n t t a a l l c c o o n n d d i i t t i i o o n n s s
Ambient temperature
Storage temperature
Climatic stability
www.kuebler.com
30 V DC/15 mA
max. 2.0 V DC
max. 0.4 V DC
voltage output 10 V DC ±2%, 30 mA
and
voltage output 24 V DC ±15%, 50 mA
only voltage output 10 V DC ±2%, 30 mA
RS232, RS485, RS422
600, 1200, 2400, 4800, 9600, 19 200 programmable
00 ... 99 programmable
8 Data bit, no parity, 1 stop bit
advanced ASCII character format of
IBM-PC without graphic characters
Housing for control panel 96 x 48 mm according to
DIN 43 700, RAL 7021
96 x 48 x 90 mm
92
+0,8
x 45
+0,6
mm
approximately 83 mm
approximately 220 g
IP 65 (on the front side)
1 x screw terminal, 8-pole, RM 5.08
1 x screw terminal, 11-pole, RM 3.81
(*) 1 x screw terminal, 5-pole, RM 3.81
The front of the unit is only to be cleaned
with a soft wet (water !) cloth.
–10°C ... +50°C
–20°C ... +70°C
relative humidity < 75%, without condensation
Seite 7