TS Industrie SUPER PREMIUM 30 ER Manual Tecnico página 46

Tabla de contenido

Publicidad

Normal and high speed function
The rotor speed is indicative of the functioning on the machine.
The message RPM too low indicates that
the engine RPM, and consequentially, the
rotor speed, is not sufficient to allow the
forward feed action of the feed rollers.
To avoid the engine stopping after display of the message SLIPPAGE, accelerate in mid-regime without
exceeding 1850 rpm (for the ER model) or 2100 rpm (for the DR model) and engage the rotor clutch.
the engine speed to maximum: a smiley
indicates when the minimum rotor speed
for forward feed action has been reached.
The Yellow forward button can now be
pressed.
Once the feed rollers are in action, if the red
stop bar to the rear of the hopper is pus-
hed, feeder stop is displayed.
If the rotor speed is too high, the feed roller
is automatically stopped to prevent use of
the machine and a Danger symbol is dis-
played along with the message Rotor over
speed.
To restart the rotation of the feed rollers,
the engine must be slowed. It can be retur-
ned to maximum only once the cause of the
over speed has been rectified.
To avoid the engine stopping after display of the message SLIPPAGE, reduce the speed to ticking
over, then release the clutch.
Super PREMIUM ER / DR / DRI
D E S C R I P C I Ó N Y
M A N I P U L A C I Ó N
Increase
46
26/06/2013

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Super premium 35 drSuper premium 35 dri