Filtrete 3US-AS01 Instrucciones De Instalación Y Funcionamiento página 6

Ocultar thumbs Ver también para 3US-AS01:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

ATTACH THE FILTER:
You will need: fi lter cartridge (A)
1. Insert the fi lter cartridge (A) into the
bracket (B).
2. Push fi lter up, then turn one quarter
of a turn to the right until it stops.
(Fig. 13)
3. When properly attached, there will
be NO gap between the bracket (B)
and the fi lter cartridge (A).
TURN WATER ON:
1. Turn the water back on at the
cold water shutoff valve. (Fig. 14)
2. Run water to fl ush 10 gallons (37.85 liters)
through the system before use.
(Approximately 5-7 minutes.)
3. Check for leaks. If any dripping or leaking
occurs, turn cold water supply off, tighten
fi ttings and assure that tubing is pushed
completely into fi ttings.
YOUR SYSTEM IS NOW READY FOR USE.
FILTER CARTRIDGE
REPLACEMENT
INSTRUCTIONS:
Caution: To reduce the risk of property damage due to
water leakage, replace disposable fi lter every six months.
NOTE: You do NOT need to shut off your water supply when changing your fi lter cartridge.
The system will automatically shut off the water supply while fi lter is being changed.
REPLACING FILTER
1. Grasp cartridge and turn to the left briskly until cartridge will not turn any further.
(Turn quickly to avoid pressure release that may result in leaks.)
2. Gently pull cartridge downward to remove.
3. Align tabs of new fi lter cartridge with mounting bracket and insert new fi lter cartridge
into the bracket. (Fig. 15) Turn cartridge to the right until cartridge stops.
4. Run water to fl ush 10 gallons (37.85 liters) through the system before use.
(Approximately 5-7 minutes.)
6
(Fig. 13)
C09093B-A5
Filtrete a 3M Brand
3US-PS01
C09093B-A5
Filtrete a 3M Brand
3US-PS01
C09093B-A5
Filtrete a 3M Brand
3US-PS01
(Fig. 14)

Publicidad

Tabla de contenido
loading

Productos relacionados para Filtrete 3US-AS01

Este manual también es adecuado para:

3us-ps01

Tabla de contenido