For walls or floors having ceramic tile covering, drill
3/16'' (5 mm) holes through the tile only, then drill into
the material behind the tile as indicated immediately
above.

Mounting Anti-Tip Bracket

The floor mounted bracket shall be installed as follows:
1. Place bracket on floor in position shown in Figure 8.
30'' and 36'' bracket may be used in either corner
of the installation area.
2. Secure to floor and wall stud using the (4) 1½'' (38 mm)
Phillips head screws provided.
3. Later, when the unit is installed, the adjustable leg will
slide under the bracket, as shown in Figure 8.
4. If the range is moved to a new location, the Anti-Tip
Device must be removed and reinstalled.
C L
x x
Range
Side
30''
Left or Right
36''
Left or Right
48''
Left or Right
Figure 8: Placement of Anti-Tip Bracket
STEP 5: Gas Requirements
and Hookup
Verify the type of gas being used at the installation site. As
shipped from the factory, units are configured for use with
only natural gas or propane (LP) gas. Make certain the
range matches the type of gas available at this location.
These ranges are NOT convertible between different
types of gas.
Installation Instructions
C L
x x
Distance of X
2¼'' (57 mm)
2 '' (67 mm)
2½'' (64 mm)
This appliance has been CSA certified for safe operation
up to an altitude of 2,000 ft (610 m) elevation above sea
level.
High Altitude — For altitudes above 2,000 feet (610 m)
elevation above sea level, adjustments can be made with
the High Altitude Packet included with the unit. If flame
performance is satisfactory, the contents in this packet will
not be required. It is required that a Certified Professional
make the high altitude adjustments during installation.
NATURAL GAS REQUIREMENTS:
Inlet Connection:
½'' (
[Minimum ¾" (19 mm) dia. flex
line]
Supply Pressure:
6" min. to 14" max. water column.
(14.9 to 34.9 mb)
Manifold Pressure:
5" water column (12.5 mb)
PROPANE GAS REQUIREMENTS:
Inlet Connection:
½'' (
[Min. 3/4" (19 mm) dia. flex line]
Supply Pressure:
11" min. to 14"max. water column.
(27.4 mb to 34.9 mb)
Manifold Pressure:
10" water column (24.9 mb)
WARNING
Gas line must not come in contact with any components
inside back cover of range.
CAUTION
When connecting unit to propane gas, make certain the
propane gas tank is equipped with its own high pressure
regulator in addition to the pressure regulator supplied
with the appliance. The pressure of the gas supplied to
the appliance regulator must not exceed 14" water
column (34.9 mb).
Hook Up
The gas supply connections shall be made by a competent
technician and in accordance with local codes or
ordinances. In the absence of local codes, the installation
must conform to the National Fuel Gas Code ANSI Z223.1/
NFPA54- current issue.
1. A manual gas shut-off valve must be installed external
to the appliance, in a location accessible from the front,
for the purpose of shutting off the gas supply. The
supply line must not interfere with the back of the unit.
Make sure the gas supply is turned off at the manual
shut-off valve before connecting the appliance.
) NPT internal
13 mm
) NPT internal
13mm
English 14