Operation; Starting The Engine; Connecting Consumers To The Generator; Switching Off The Engine - Parkside PSE 2800 A1 Instrucciones De Utilización Y De Seguridad

Generador eléctrico
Ocultar thumbs Ver también para PSE 2800 A1:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

Anleitung_4152413:_
22.10.2010

7. Operation

Important. You must fill up with engine oil
(approx. 0.6 l) and fuel before you can start the
engine.
Check the fuel and engine oil levels and top
up if necessary.
Make sure that the generator has sufficient
ventilation
Make sure that the ignition cable is secured
to the spark plug.
Inspect the immediate vicinity of the
generator.
Disconnect any electrical equipment which
may already be connected to the generator.

7.1 Starting the engine

Important.
When starting with the reserve starter (12), the
motor may recoil suddenly as it starts up,
resulting in hand injuries. Wear protective
gloves when starting the equipment.
Open the petrol cock (13) by turning it down
Set the ON/OFF switch (10) to the "ON"
position
Move the choke lever (11) to position I Ø I.
Start the engine with the reversing starter
(12), by pulling forcefully on the handle. If
the engine does not start, pull the handle
again.
Push the choke lever (11) back after the
engine has started.

7.2 Connecting consumers to the generator

Connect the equipment you want to use to
the 230 V~sockets (3).
Important: These sockets may be loaded
continuously (S1) with 2600W and temporarily
(S2) for a maximum of 2 minutes with 2800W.
The generator is suitable for 230 V~ AC
appliances only.
Do not connect the generator to the
household mains system as this may result
in damage to the generator itself or to other
electrical appliances in your home.
13:02 Uhr
Seite 47
Note: Some electrical appliances (power
jigsaws, drills, etc.) may have a higher level of
power consumption when used in difficult
conditions

7.3 Switching off the engine

Before you switch off the generator, allow it
to run briefly with no consumers so that it
can "cool down".
Set the ON/OFF switch (10) to the "OFF"
position.
Close the petrol cock (13).
7.4 Overload cut-out 2 x 230 V socket-
outlets
Important. The generator is fitted with an
overload cut-out.
This shuts down the sockets (3). You can
restart the sockets (3) by pressing the overload
cut-out (5).
Important. If this happens, reduce the
electric power you are taking from the
generator or remove any defective
connected appliances.
Important. Defective overload cut-outs
must be replaced only by overload cut-outs
of identical design and with the same
performance data. If repairs are necessary,
please contact your customer service
center.
GB/
MT
47

Publicidad

Tabla de contenido
loading

Tabla de contenido