OPERATION
Depending on the model, the unit is equipped with the following controls:
Controls shown in Fig. 11: Button A = turns the lights on/off. Button B = turns the TIMER on/off: press
once to turn the timer on, therefore, after 5 minutes, the motor cuts out (at the same time the selected speed
blinks on the display); the timer remains on if the motor speed is changed. Display C = - indicates the selected
motor speed (from 1 to 4); - indicates Timer On when the number blinks; - indicates Filter Alarm when the central
segments is on or blinking. Button D = makes the motor work (at the last speed selected); pushing the button
again, the speeds of the motor are sequentially selected from 1 to 4; keeping this button pressed for about 2
seconds shuts down the motor. Button R = resets the grease filters or charcoal filters; when the filter alarm
appears (i.e. when the central segment on the display goes on), the grease filters must be cleaned (30 hours
of operation); when the central segment starts blinking, the grease filters must be cleaned and the charcoal filters
replaced (120 hours of operation). Obviously, if the hood is not a filtering model and does not have a charcoal
filter, clean the grease filters both when the central segment goes on and when it starts blinking. The filter alarm
can be seen when the motor is off and for about 30 seconds. To reset the hour counter, keep the button pressed
for 2 seconds while the alarm can be seen.
Controls shown in Fig. 12:
Button TC1 (Lights): Switches main light ON/OFFWhen the main light is on, BL1 changes colour and becomes active.When
the button is pressed for more than a second, it switches the courtesy lights (optional) on/off.
Button TC2 (Motor-V1): Motor ON/OFF - Activates the motor at 1st speed.
Button TC3 (Motor-V2)Activates the motor at 2nd speed.
Button TC4 (Motor-V3)Activates the motor at 3rd speed.
Button TC5 (Motor-V4)Activates the motor at 4th speedMaximum speed is timed at a maximum of 5 minutes, after which
3rd speed is set automatically.When the motor is active, the LED of the last selected button (TC2-TC5) active to signal
which speed has been set.
Button TC6 (TIMER auto power off 5 min.)Activates the TIMER function at the speed that has already been selectedIf
the motor is NOT active, it switches on the motor at the 1st speed and activates the TIMER functionWhen the TIMER
function is active, BL6 becomes active.
30h filter ALARM: after 30 hours of operation, an alarm switches on to signal the need for anti-grease filter cleaning.The
filter alarm, when active, is displayed for 30 sec each time the motor is deactiva-ted:BL6 remains ON.During this period,
it is possible to reset the alarm by pressing the TC6 button for longer than a second.
120h filter ALARM: after 120 hours of operation, an alarm switches on to signal the need for active carbon filter (optional)
replacement.The filter alarm, when active, is displayed for 30 sec each time the motor is deactiva-ted:BL6 lighting
blinking.During this period, it is possible to reset the alarm by pressing the TC6 button for longer than a second.
Work Time Limit: if the hood is left on (lights and/or motor), after 10 hours in the absence of commands from the user,
it will automatically switch to OFF condition with all services switched off.
Buzzer: the Buzzer emits a "beep" each time that a command is set from the keyboard or remote control (optional).
Controls shown in Fig. 13:
Button TC1 (Lights): Switches main light ON/OFFWhen the main light is on, BL1 changes colour and becomes
active.When the button is pressed for more than a second, it switches the courtesy lights (optional) on/off.
Button TC2 (Motor-V1)Motor ON/OFF - Activates the motor at 1st speed.
Button TC3 (Motor-V2) Activates the motor at 2nd speed.
Button TC4 (Motor-V3)Activates the motor at 3rd speed.
Button TC5 (Motor-V4)Activates the motor at 4th speedMaximum speed is timed at a maximum of 5 minutes, after which
3rd speed is set automatically.When the motor is active, the LED of the last selected button (TC2-TC5) active to signal
which speed has been set.
Button TC6 (Auto ASC)Activates/deactivates the automatic ASC function.In this mode, motor speed increases or
decreases depending on the quantity of smoke and odours being produced under the hood. When the function is active,
BL6 becomes active.Each time that the motor changes speed, either automatically or forced by the user, BL6 lighting
blinking for a few seconds.
30h filter ALARM: After 30 hours of operation, an alarm switches on to signal the need for anti-grease filter cleaning.The
filter alarm, when active, is displayed for 30 sec each time the motor is deactivated:BL6 remains ON.During this period,
it is possible to reset the alarm by pressing the TC6 button for longer than a second.
120h filter ALARM: After 120 hours of operation, an alarm switches on to signal the need for active carbon filter (optional)
replacement.The filter alarm, when active, is displayed for 30 sec each time the motor is deactivated: BL6 lighting
blinking.During this period, it is possible to reset the alarm by pressing the TC6 button for longer than a second.
Buttons TC5 + TC6 (ASC sensitivity): ASC odour sensor sensitivity can be varied on 4 different levels as needed by pressing
buttons TC5 and TCS simultaneously for more than 1 second.The motor must be OFF and automatic function NOT
active.When sensitivity setting function is activated:all BL switch OFF (no display) then BL6 activates FIX.After 1 second,
the BL2-BL5 LEDs will show the set sensitivity value, BL2 for lower sensitivity up to BL5 which indicates higher sensitivity.
You can set a different value using corresponding keys TC2, TC3, TC4 or TC5. To save the new sensitivity, press TC6
or wait until the function deactivates automatically.
It can be varied on your keyboard (for cleaning) with a long press of the buttons TC1 and TC6 simultaneously. When the
cleaning mode is active, the keys TC1 and TC6 remain lit. To exit cleaning is necessary to activate the buttons again
TC1 and TC6 pressed simultaneously (long), or wait for 5 minutes.