Passive Infrared Vacancy Sensors RMS100, RMS120 and
Passive Infrared Occupancy Sensors RMS101, RMS121
Vacancy and Occupancy sensors use passive infrared detection and a microcontroller to maximize energy savings and
minimize turning off lights in an occupied room.
Hubbell offers 4 models:
Vacancy Sensor: RMS100, RMS120 120VAC, 60 Hz (Ivory, White, Almond, Light Almond)
Occupancy Sensor: RMS101, RMS121 120VAC, 60 Hz (Ivory, White, Almond, Light Almond)
Lighting Load: 120VAC: 25Watts minimum, 500Watts maximum incandescent only (Do not use with
fluorescent lamps).
Time Delay: Manual adjustment behind front press switch: 30 second minimum, 30 minutes maximum.
Daylight Control (Occupancy Sensor Only): Press one button to set ambient light level (Photocell).
Manual Override Front Press Switch (FPS): Switches lights "on" or "off", (See Front Press switch Basic
Operation Below). Note: FPS must be pressed to turn light on.
Motion Indicator: Highly visible green LED.
Reset to Factory Setting: Hold front press switch for 10 seconds resets the sensor to the factory settings.
50% dim down: Lights dim to 50% 30 seconds before they switch off.
Coverage Area approximately 800ft² (74m²) See coverage area below.
Passive infrared (IR) sensors are activated by changes in IR temperature in the coverage area.
The product must be installed in the line-of-sight of the occupant. The sensor should not be installed:
16'
16'
NOTICE: Designed for hard wire circuits only, do not use to control receptacles. For installation by a qualified electrician
in accordance with national and local electrical codes and the following instructions.
CAUTION: RISK OF ELECTRIC SHOCK. Disconnect power before installing.Never wire energized electrical
components. Mandate required OSHA lockout, tag out procedures.
CAUTION: USE COPPER CONDUCTORS ONLY.
CAUTION: Use only in indoor, dry locations. Sensor's maximum operating ambient temperature = 50ºC.
CAUTION: To Reduce the Risk of Overheating And Possible Damage To Other Equipment, Do Not Install
To Control A Receptacle, A Motor-Operated Appliance, A Florescent Lighting Fixture, Or A Transformer-
Supplied Appliance.
Single-Gang Installation ONLY
INSTALLATION INSTRUCTIONS
35'
Horizontal Coverage
Mounting
Height
36" to 54"
(91.44 to 137.16 cm)
35'
Vertical Coverage
PD2203

Publicidad

loading

Resumen de contenidos para Hubbell homeSELECT RMS100

  • Página 1 Vacancy and Occupancy sensors use passive infrared detection and a microcontroller to maximize energy savings and minimize turning off lights in an occupied room. Hubbell offers 4 models: Vacancy Sensor: RMS100, RMS120 120VAC, 60 Hz (Ivory, White, Almond, Light Almond)
  • Página 2: Installation Instructions

    Hubbell Incorporated (Delaware) 185 Plains Road Milford, CT 06461-2420 (203) 882-4800 Passive Infrared Vacancy Sensors RMS100, RMS120 and Passive Infrared Occupancy Sensors RMS101, RMS121 INSTALLATION INSTRUCTIONS Pre-installation Checklist 1. Check rating of sensor to make sure it is suitable for the application. RMS100, RMS120 sensors are to be used with 120VAC, 60 Hz, 25Watts minimum, 500Watts maximum incandescent load ONLY.
  • Página 3: Directives De Montage

    Les capteurs d'absence et de présence utilisent la détection infrarouge passive et un microcontrôleur pour optimiser les économies d'énergie et minimiser la fermeture des lumières dans une pièce occupée. Hubbell offre 4 modèles : Capteurs d'absence : RMS100, RMS120 120 V CA, 60 Hz (ivoire, blanc, amande, amande pâle) Capteurs de présence : RMS101, RMS121 120 V CA, 60 Hz (ivoire, blanc, amande, amande pâle)
  • Página 4 Hubbell Incorporated (Delaware) 185 Plains Road Milford, CT 06461-2420 (203) 882-4800 Capteurs d'absence à infrarouge passifs RMS100, RMS120 et capteurs de présence à infrarouge passifs RMS101, RMS121 DIRECTIVES DE MONTAGE Vérifications préliminaires au montage 1. S'assurer que les caractéristiques nominales du capteur conviennent à l'application. Les capteurs RMS100 et RMS120 conviennent à...
  • Página 5 Los sensores de ausencia y de presencia utilizan detección infrarroja pasiva y un microcontrolador para maximizar los ahorros de energía y minimizar el apagado de las luces en una habitación ocupada. Hubbell ofrece 4 modelos: Sensores de ausencia: RMS100, RMS120 120 V~, 60 Hz (marfil, blanco, almendra, almendra claro) Sensores de presencia: RMS101, RMS121 120 V~, 60 Hz (marfil, blanco, almendra, almendra claro) Carga de alumbrado: 120 V~: 25 W mínimo, 500 W máximo sólo incandescente (no debe usarse con lámparas fluorescentes).
  • Página 6 S.A. DE C.V. HUBBELL reparará o reemplazará a su juicio el producto en un plazo de 60 días. Esta Av. Coyoacán N° 1051 garantía no cubre desgastes por uso normal o daños ocasionados por accidente, mal...

Este manual también es adecuado para:

Homeselect rms120Homeselect rms101Homeselect rms121