Before using the DMX512 controller, you should set the channel address.
can be set between 001~511. Every binary address switch has a digital no.
Please refer to:
No.
Digital No.
1st
1
2nd
2
3rd
4
4th
8
5th
16
DMX Control Parameter Chart
DMX512
Channel No
fig.
0~69
70~139
Channel 1
Control
140~209
mode
210~255
Pattern
0~33
Channel
Selection
2
34~255
Channel
Strobe
3
Channel
Spot and
0-255
4
line
1~160
Horizontal
161~190
move
Channel
191-220
5
221-255
Channel
1~160
6
161~190
©Copyright Lotronic 2013
No.
Digital No.
6th
32
7th
64
8th
128
9th
256
10th
Function switch
Content
Shut off
Sound control
Auto play
manual
Static pattern
Dynamic Geometric
pattern
8 grade speed
0-255
0-255)/30=0-8do
From line to spot effect
Manual
From left to right move
From right to left move
Right and left in-phase
move
Manual
From down to up
Vertical
move
Zoom(+/-)
Channel
pattern size
7
It
Channel
Color
8
selection
Channel
Reset
9
Channel
Gradually
10
paint
Warning
Power off before installation or maintenance.
LASER RADIATION !
DANGEROUS EXPOSURE TO LASER RADIATION
CLASS 3B LASER
ONLY FOR PROFESSIONAL USE
Maintenance
☆ Please clean the lens regularly. Do not do it using the wet cloth or other
chemical. The cleaning frequency depends on the using frequency and
surrounding conditions. It is recommended to clean the unit every 3
weeks.
☆ Please clean the lighting surface and engine outlet regularly.
☆ Be sure that there is no flammable or explosive subject nearby. The
least distance is 0.5 meters. at the same time, keep more than 15cm
between the wall and laser lighting;
Electric products must not be put into household waste. Please bring them to a
recycling centre. Ask your local authorities or your dealer about the way to
proceed.
191~220
From up to down
Up and down in-phase
221~255
move
0-255
pattern size change
0-255
If the number exceeds
0-255
200, the unit will reset
0-255
Gradually paint
3